9c
MAKE WIRED CONNECTIONS: HARD WIRED VERSION
Important: Align the polarity markings (7) on the
wire ends when making the connections.
Note: Contractor to supply ELECTRICAL BOX (11).
1. Connect the SOLENOID WIRE (1) to the RED
AND BLACK WIRE (2) in the flush valve head.
2. Connect black and white power line connections
to HARD-WIRED AC TRANSFORMER (12) and
mount onto ELECTRICAL BOX (11)
3. Thread EXTENSION CABLE (4) through the WIRE
CHANNEL (6) and through HOLE (8) in the back
of the flush valve head. Connect one end of the
supplied EXTENSION CABLE (4) to the BACK-UP
BATTERY (14) and connect the other end of CABLE
(4) to the BLACK AND PURPLE WIRE (5).
4. Connect BATTERY BACK-UP (14) to
HARD-WIRED AC TRANSFORMER (12).
Note: Do not tighten flush valve head at this point.
Note: Power to the circuit must be deenergized
while making hard wired connections.
6
8
2
5
1
4
11
4" CONTROL BOX
OR EQUIVALENT BY
OTHERS (6)
7
4
27' EXTENSION
14
BLACK & WHITE
POWER
12
CONNECTIONS