American Standard DetectLink 6072121 Manual page 12

Table of Contents

Advertisement

Available languages

Available languages

9d
CONT'D MULTI-AC VERSION (DAISY CHAIN); (PK00.MAC POWER KIT)
Unit #1
Already installed
BLACK & WHITE
TO FLUSH
POWER
VALVE SOLENOID
CONNECTIONS
4
5
3a
(See AC version installation
instructions, page 6)
Important: Disconnect AC Power Supply from wall outlet before making daisy-chain connections.
Note: For Unit #1 installation instructions, refer to AC version section (page 9).
For subsequent Units...
1. Take the first 27" EXTENSION CABLE (1) and connect one end to the solenoid cable and connect the
other end to a sensor cable.
2. Take the second 27" EXTENSION CABLE (2) and connect one end to the available sensor
cable, the other end to the BATTERY BACK-UP KIT (5).
3. Connect the other end of the BATTERY BACK-UP KIT (5) to one of the two terminals at the one end of
Y-ADAPTER (3).
4. Take the 10' EXTENSION (4) and connect one end to the single terminal of Y-ADAPTER (3), and
the other end to available terminal of the previous unit's Y-ADAPTER (3a).
5. Repeat process for each subsequent unit.
6. Place Y-ADAPTERS (3) into respective electrical box.
7. Plug in AC power supply into wall outlet once all daisy-chain unit connections have been made.
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components will void the warranty.
Unit #2
1
2
TO FLUSH
VALVE SOLENOID
5
3
4
MAXIMUM OF 8 UNITS PER POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
Unit #3
TO FLUSH
VALVE SOLENOID
Unit #4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Detectlink 607b121

Table of Contents