GS700TP Smart Switch Software Administration Manual
To define bandwidth settings:
1. Click QoS > CoS > Basic > Bandwidth. The Bandwidth screen displays:
Figure 5-4
The Bandwidth screen contains the following fields:
Interface – Displays the ports for which the bandwidth settings are displayed.
Ingress Rate Limit Status – Select whether rate limiting is defined on the interface. The
possible field values are:
Enable – Enable ingress rate limiting on the interface.
Disable – Disable ingress rate limiting on the interface.
Ingress Rate Limit – Enter the rate limit in kilobits per second. The possible field range is
3500 to the maximum port speed. GE (Gigabit Ethernet) ports have a maximum speed of
1000000 kilobits per second. The field default value is 3500.
Egress Shaping Rates Status – Select whether egress shaping is defined on the interface.
The possible field values are:
Enable – Enable egress shaping rate on the interface.
Disable – Disable egress shaping rate on the interface. This is the default value.
5-6