6.2

Expansion modules (M.2)

6.2.1

Usable expansion modules (M.2)

The expansion modules (M.2) are referred to as M.2 modules below.
An M.2 module that complies with the following specifications is supported:
Dimensions
Interface
Protocols
WLAN module
WWAN module, e.g. LTE/ 5G
Field Bus
M.2 NVMe SSD
Artificial Intelligence
Special (Digital IO)
1
Conditions of use of M.2 modules
• The dimensions of the M.2 modules must not exceed the specified dimensions. If the
dimensions are exceeded, you may experience contact problems, malfunctions and
difficulties with the assembly.
• The connecting cable between M.2 modules and conditioner card should be at least 150
mm long.
See also
Position of the interfaces on the motherboard (Page 82)
Dimension drawing of expansion modules (M.2) (Page 75)
SIMATIC IPC PX-32A
Operating Instructions, 09/2023, A5E53092695-AA
, e.g. WiFi
1
Key E/Key A+E is also possible via M.2 Key E-Key B adapter
Expanding and assigning parameters to the device
6.2 Expansion modules (M.2)
M.2 module 1 (X100)
2230, 2242, 2260, 3030, 3042
1 × PCIe 3.0 x2 lane
1 × USB 2.0
Key B
x
x
x
-
x
x
49