Whirlpool Pro-Style Manual page 23

Gas convection ranges 30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) for residential use only
Table of Contents

Advertisement

Available languages

Available languages

Reconnect Gas and Electricity:
1. Open the manual shut-off valve in the gas supply line.
The valve is open when the handle is parallel to the
gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear,
a leak is indicated. Correct any leak found.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
3. Plug into a grounded 3 prong outlet.
4. Turn on power supply. For further information, please refer
to the user instructions located in the Use and Care Guide.
5. Refer to the "Electronic Ignition System" section in the
Installation Instructions for proper burner ignition, operation
and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Check flames. Checking for proper cooktop burner flame
is very important. The small inner cone should have a very
distinct blue flame ¼" (0.64 cm) to ½" (1.3 cm) long. The
outer cone is not as distinct as the inner cone. LP gas
flames have a slightly yellow tip.
B
23

Advertisement

Table of Contents
loading

Table of Contents