Whirlpool Pro-Style Manual page 16

Gas convection ranges 30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) for residential use only
Table of Contents

Advertisement

Available languages

Available languages

Line pressure testing above ½ psi gauge (14" WCP)
The range and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP)
or lower
The range must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
Convert Oven Bake Burner (30" [76.2 cm] and 36"
[91.4 cm] models and the Right Oven Cavity on 48"
[121.9 cm] models)
1. Slide the bake burner cover to the right or left.
A
A. Bake burner cover
2. Lift up and remove oven bake burner cover and set aside.
3. Using a 7 mm nut driver, unscrew oven baffle nuts and
remove oven baffle. Set aside.
A. Oven baffle
B. Oven baffle nuts
16
A
B
4. Remove the oven bake burner screws and oven bake
burner and gently set aside.
A. Oven bake burner screws
B. Oven bake burner
C. Oven bake burner electrode bracket
D. Oven bake burner electrode
5. Lift up clip on the oven bake burner electrode bracket
with a finger or flat-blade screwdriver and pull away
the electrode.
A. Oven bake burner electrode bracket
B. Electrode bracket clip
D
C
A
B
B
A

Advertisement

Table of Contents
loading

Table of Contents