Whirlpool Pro-Style Manual page 15

Gas convection ranges 30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) for residential use only
Table of Contents

Advertisement

Available languages

Available languages

Remove Kick Plate
Option 1
1.
Remove foam between door and kick plate.
2.
Using a Phillips screwdriver, remove screws from
kick plate.
A
A. Kick plate
B. Remove these screws.
3.
Lift up on kick plate to release plate from
shoulder screws.
4.
Lay kick plate to the side to avoid scratching
the stainless steel.
Option 2
1.
Remove kick plate from top of range and grate pack.
A. Kick plate
In packaging
A. Kick plate
Packaging removed
2.
Lay kick plate to the side to avoid scratching
the stainless steel.
3.
Remove screws from range.
A. Remove these screws.
B
A
A
Convert Gas Pressure Regulator
1. Locate the gas pressure regulator at the left rear
of the range.
A
A. Gas pressure regulator
2. Remove the gas pressure regulator cap by using a
large flat-blade screwdriver, turning the regulator cap
counterclockwise.
NOTE: Do not remove the spring beneath the cap.
3. Turn over the gas pressure regulator cap, and reinstall
on the regulator so that the hollow end faces out and
the letters "NAT" are visible.
4. Tighten the gas pressure regulator cap by using a large
flat-blade screwdriver, turning the regulator cap clockwise.
5. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure
to the regulator should be as follows for operation and
checking the regulator setting:
Natural Gas:
Minimum pressure 6" (15.2 cm) WCP
Maximum pressure 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.