3.5 Display elements and operator controls
Door and locking cylinder, rear
There are two additional locking cylinders of the same type on the rear of the charging
station in the two twist levers.
To open the rear door of the device, turn the two folded-out twist levers inwards. First, tilt the
upper part of the door slightly. After that, lift the door out upwards. On the left side, the
ground cable connects the door and the cabinet.
Proceed in reverse order when inserting the door. First thread the door in at the bottom
again. Then press the upper part of the door against the cabinet on the left side. Turn the
twist levers outwards and lock the door.
Figure 3-6  Locking cylinder, rear
To maintain the industrial security concept, replace the supplied locking cylinders with your
own standard half cylinders (10/30) according to DIN 18252.
1. Unlock the levers to deflect them.
2. Remove the fixing screw in the folded-out lever.
3. Remove the locking cylinder.
Install your own locking cylinder in the reverse order. The maximum torque of the fixing
screw is 2.5 Nm.