Blade To Table; Blade Guard; Replace; Outlet - Craftsman 113.24181 Owner's Manual

12-inch motorized table saw
Table of Contents

Advertisement

If
tooth
does not
touch
the
same amount
...
the
mechanism underneath
must be adjusted to make the blade
PARALLEL
to GROOVE.
NOTE: Make sureTILT
CLAMP KNOB istightened.
1. Lay the saw on its LEFT SIDE.
2.
Loosen Hex. Head screw "A"
between 1/4 and 1/2
turn, using a 5/8 in. socket wrench with an extension.
3. Tilt blade to 45 ° and loosen screw "B".
4. Place saw in upright position..,
tilt blade to 90 °.
5.
Remove blade..,
lower the motor all the way down.
6. Reach inside of the insert opening and loosen screws
"C" and "D" 1/4 to 1/2 turn, usinga 5/8 in. wrench.
7.
Replace sawblade and raise it all the way up.
8. Grasp spreader bar at rear of saw and move sideways
•.. recheck blade alignment with square.
9. When blade is PARALLEL
to groove..,
tighten screws
"C'" and "'D".
10. Lay saw on its LEFT SIDE and tighten screws "'A" and
SnB01"
_-<_----.,
-__ --- _
_,,
_._._
\
f
'x_i_(_j.-,_scR_w
"D"
BLADE TILT,
OR SQUARENESS
OF BLADE TO TABLE
90 ° (SQUARE) and 45 ° (BEVEL) STOP COLLARS.
When the bevel pointer is pointing directly to the "O" mark
on the bevel scale, the sawblade should make a SQUARE
cut 90 ° to the table.
To check for SQUARENESS:
WARNING:
FOR YOUR OWN SAFETY, TURN SWITCH
"OFF"
AND
REMOVE
PLUG FROM POWER SOURCE
OUTLET.
1. Raise blade all the way UP ... raise blade guard.
2. TILT
blade a few degrees to the LEFT
... nowtilt
blade back to the RIGHT as far as it will go.
3. Place and ACCURATE
square against blade. Make sure
square is not touching the TIP
of one of the saw
TEETH.
24