Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free
PCNTNW-NW-086 The driver parameter block is too small.
PCNTNW-NW-087 The media parameter block is too small.
PCNTNW-NW-091 The hardware configuration conflicts.
PCNTNW-NW-126 The group bit in the node address override was cleared.
PCNTNW-NW-127 The local bit in the node address override was set.
PCNTNW-NW-164 The device was not found.
Link Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register with
the LSL.
Action: Check the version of the NetWare or IntraNetWare Operating
System. Make sure that this driver is correct for the version of NetWare or
IntraNetWare that you are using. Restart the server.
Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, go to "Starting the
diagnostic programs" on page 14 to run the diagnostic programs. .
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, go to "Starting the
diagnostic programs" on page 14 to run the diagnostic programs.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, go to "Starting the
diagnostic programs" on page 14 to run the diagnostic programs.
Explanation: You tried to load a new frame type for the existing controller.
The hardware assumptions made in doing so are incorrect. This error can
also occur if you try to specify a mode (such as, redundancy) that conflicts
with another specified mode.
your hardware configuration matches the software settings.
Explanation: The IEEE address has a group bit that indicates that an address
belongs to a group of stations. This bit is used only as a destination address;
it cannot be used as a source address. You tried to enter a source address
with this bit set. The driver cleared the group bit of the source address.
Action: None necessary, message is for information only.
Explanation: The local bit in the IEEE address format indicates that the
addresses are being managed locally. If you use the node address override
capabilities of this driver to enter a new address, the local bit must be set.
You entered an address without the local bit set. The driver has set the local
bit.
Action: None necessary, message is for information only.
Explanation: The driver cannot find an Ethernet controller in the server.
Action: Verify that the Ethernet controller is enabled. If the Ethernet
controller is enabled, go to "Starting the diagnostic programs" on page 14 to
run the diagnostic programs.
Action: Make sure that
21
Diagnostics