Information Panel System Error Led - IBM x 340 Series Hardware Maintenance Manual

Table of Contents

Advertisement

Information panel system error LED

Diagnostic Panel LED
All LEDs off
(Check
System Error Log for error
condition, then clear System Error
Log when the problem is found.)
CPU LED on
(The LED
next to the failing CPU should be
on.)
VRM LED on
LED next to the failing VRM
should be on.)
(The LED
DASD LED on
located next to the drive bay that
the failing drive is installed in will
be turned on.)
FAN LED on
MEM LED on
(The LED next to
the failing DIMM is on.)
NMI LED on
PCI A LED on
PCI B LED on
114
Hardware Maintenance Manual: xSeries 340 Model 6RY
The system error LED is turned on when an error is detected. If the system error LED
is on, remove the cover and check the diagnostic panel LEDs. The following is a
complete list of diagnostic panel LEDs followed by the FRU/Action for correcting the
problem. The following chart is valid only when the system error LED is on.
Note: If a diagnostic panel LED is on and the information LED panel system error
LED is off, there is probably an LED problem. Run LED diagnostics.
Notes:
1.
To locate the LEDs on the system board see "System board LED locations" on
page 44.
2.
Check the System Error Log for additional information before replacing a FRU.
3.
The DIMM error LEDs, processor error LEDs, and VRM error LEDs turn off when
the system is powered down.
1.
System Error Log is 75% full; clear the log.
2.
PFA alert; check Netfinity log for failure; clear PFA alert; remove AC power
for at least 20 seconds, reconnect, then power up system.
3.
Run Information Panel diagnostics.
1.
Processor 1 or 2.
(The
1.
Voltage regulator module indicated by the VRM LED on the system board
that is turned on.
2.
Processor indicated by the Processor LED.
1.
Failing drive.
2.
Be sure the fans are operating correctly and the air flow is good.
3.
SCSI Backplane.
1.
Check individual fan LEDs.
2.
Replace respective fan.
3.
Fan Cable.
4.
System Board.
5.
Power Backplane Board.
1.
DIMM.
2.
Failing DIMM in slot J1-J4.
1.
Reboot the system.
2.
Check the System Error Log.
1.
PCI Card in slot 5.
2.
Remove all PCI adapters from slots 1-5.
3.
System Board.
1.
Card in slots 3-5.
2.
Remove all PCI adapters from slots 1-5.
3.
System Board.
FRU/Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ry

Table of Contents