IBM x 340 Series Hardware Maintenance Manual page 131

Table of Contents

Advertisement

Error Code/Symptom
2
1301
(I
C cable to front panel not
found)
2
1302
(I
C cable from system board
to power on and reset switches not found)
2
1303
(I
C cable from system board
to power backplane not found)
2
1304
(I
C cable to diagnostic LED
board not found)
1600
(The Service Processor is not
functioning)
following before replacing a FRU:
1.
Ensure that a jumper is not installed
on J45.
2.
Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
1601
(The system is able to
communicate to the Service Processor, but
the Service Processor failed to respond at
the start of POST.)
Do the following
before replacing a FRU:
1.
Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
2.
Flash update the Service Processor.
1762
(Fixed Disk Configuration error) 1.
178X
(Fixed Disk error)
1.
Cable
2.
Front Panel
3.
Power Switch Assembly
4.
System Board
1.
Cable
2.
Power Switch Assembly
3.
System Board
1.
Cable
2.
Power Backplane
3.
System Board
1.
Power Switch Assembly
2.
System Board
1.
System Board
Do the
1.
System Board
Fixed Disk Drive
2.
Fixed Disk Cables
3.
Run Configuration/Setup
4.
Fixed Disk Adapter
5.
SCSI Backplane
6.
System Board
1.
Fixed Disk Cables
2.
Run Diagnostics
3.
Fixed Disk Adapter
4.
Fixed Disk Drive
5.
System Board
FRU/Action
Symptom-to-FRU index