Cautions When Connecting C.o. Lines; Connecting Common C.o. Lines; Figure 6.1 Rj-45 Port Of The 8Trk And 4Trm - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 6. Ошибка! Используйте вкладку "Главная" для применения 제목 1 к тексту, который должен здесь
отображаться.
6.2 Connecting C.O. Lines
This section describes how to connect a common C.O. line (4TRM, 8TRK, 8TRK2, and
16TRK), Leased line (4HTRK), BRI C.O lines (2BRM and 4BRI) and T1/E1/PRI C.O.
lines (TEPRIa).

6.2.1 Cautions when Connecting C.O. Lines

Take care of followings to prevent bodily injuries and system damages when connecting
C.O. lines:
Do not connect C.O. lines in extreme weather conditions such as storm and lightning.
Do not connect C.O. lines in areas with moisture.

6.2.2 Connecting Common C.O. Lines

Connecting to the 8TRK Board and 4TRM Daughter Board
Use a pair of cable with AWG #24 (or AWG #26) width to connect a common C.O. line to
the terminal pin of a terminal box connected to the OfficeServ 7200 equipped with an
8TRK.
Pin No.
Function
6-2

Figure 6.1 RJ-45 Port of the 8TRK and 4TRM

1
2
3
-
-
-
P1~P8 Port
(RJ-45)
4
5
6
C.O.
C.O.
-
TIP
RING
© SAMSUNG Electronics Co., Ltd.
7
8
-
-