3.2.3 Connecting MP20 to LCP
If the OfficeServ 7200 consists of a basic cabinet and an extension cabinet, connect the
MP20 to the LCP using extension cables to transmit and receive signals between the
control boards.
1) Three extension cables are needed to connect the MP20 to the LCP.
2) With an extension cable, connect the 'Link1' port in MP20 mounted on the basic
cabinet and the 'Link1' port in LCP mounted on an extension cabinet.
3) With another extension cable, connect the 'Link2' port in the MP20 and 'Link2' port in
the LCP.
4) With other cable, connect the 'Link3' in the MP20 and the 'Link3' in the LCP.
© SAMSUNG Electronics Co., Ltd.
Figure 3.9 Extension Cables
LINK1
LINK3
LINK2
Figure 3.10 Connecting MP20 to LCP
OfficeServ 7200 Installation Manual
3-13