Figure 3.16 Setting The Jumpers Of Plim2 - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

Interlocking with IP phones via PLIM
If the system interworks with IP phones from the internal power via the PLIM, up
to 16 IP phone can be interworked and the remained Digital Phone (DGP) can be
interworked up to 24 DGP on the basis of 2-line LCD.
3.3.1.4 PLIM2
PLIM2 (PoE LAN Interface Module) can use PSU (Power Supply Unit) or an external
rectifier and selects the power supply source by using shunt pins.
Jumper Setting
When using the internal rectifier
The shunt pins (J2, J3 and J4) are connected between pin1 and pin2.
Since the available capacity is limited to PSU, the use of ports is limited to 16 ports
and the use of digital phones is, also, limited. (For more information on the limitation
about the use of digital phone phones in accordance with the use of PLIM2 port,
contact your dealer.)
For the use of an external rectifier: The shunt pins (J2, J3 and J4) are connected
between pin2 and pin3. There is no restriction on the use of an external rectifier
because each of them can supply the current of 10 A. Limit each current running
through PLIM2 ports below 0.1 A and in the module below 1.6 A.
Each jumper is numbered in ascending order from the marked '1' in the following
© SAMSUNG Electronics Co., Ltd.
1
1
1
J4
J3
J2

Figure 3.16 Setting the jumpers of PLIM2

OfficeServ 7200 Installation Manual
figure.
3-19

Advertisement

Table of Contents
loading