10. Conversion To Lp Gas; Hotplate - Rangemaster INC110DFFBL User's Manual & Installation Instructions

Table of Contents

Advertisement

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

10. Conversion to LP Gas

Fig. 10.1
A
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
Fig. 10.2
Art No 215-0028 - Handrail fascia fixings
Fig. 10.3
ArtNo.0102-0011 - Screwing
the control valve bypass screw
B
C
Check the 'Technical Data' section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could
n
n
invalidate any warranty or liability claims and lead
to prosecution.
When servicing or replacing gas-carrying
n
n
components disconnect from the gas supply before
starting operation. Check the appliance is gas sound
after completion.
DO NOT use reconditioned or unauthorised gas
n
n
controls.
Disconnect from the electricity and gas supply
n
n
before servicing.
Before electrical reconnection, check that the
n
n
appliance is electrically safe.

Hotplate

Injectors
Remove the burner caps and heads. Remove the old jets
(Fig. 10.1). Fit the new jets (see the 'Technical Data' section at
the back of this book for the correct jets). Reassemble in the
reverse order.
Tap Adjustment
Removing the Control Panel
To remove the handrail, remove the two end bracket fixing
screws. (Fig. 10.2). These may be hidden by removeable
covers. Pull these to remove.
Pull off all the control knobs and remove the fixing screws
underneath the control panel.
Lift the control panel and pull forwards, taking care not to
damage or strain the wiring.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig. 10.3).
Refit the control panel.
30