Programming UP Limit:
1. Press and hold the UP arrow button on the opener for 2-5
seconds.
The LONG LED will turn BLUE. Release button.
ROUND
The
LED will then flash BLUE.
2. Press and hold the UP arrow button until door is fully open.
Use both UP and DOWN buttons to adjust open travel as
necessary.
3. Press and release the SET/PRGM button
Both LEDs will flash BLUE then go out.
SECTIONAL DOOR UP LIMIT:
Door should fully open so that door seal is about even with door header. Do
not adjust so much that the door will bend, buckle or stretch door spring
cables backward.
The UP limit is now programmed.
IF UP LIMIT SETTING IS ALTERED, ALL FOLLOWING STEPS ON PAGE 20 MUST BE PERFORMED TO LOCK IN THE
FORCE PROFILE FOR PROPER DOOR OPERATION.