Genie SC 1500, TriloG 1200 Operation & Maintenance Manual

Genie SC 1500, TriloG 1200 Operation & Maintenance Manual

Screw/belt/chain drives
Hide thumbs Also See for SC 1500, TriloG 1200:

Advertisement

GARAGE DOOR OPENER MODELS
®
TM
®
TM
PowerMax
1200/1500, SC 1200/1500, TriloG
1200/1500, PowerLift
900, GPower
900,
®
®
SilentMax
1000/1200, CB 1000/1200, IntelliG
1000/1200
SCREW/BELT/CHAIN DRIVES
OPERATION & MAINTENANCE MANUAL
Includes INTELLICODE
®
2 Remote Control. Safe-T-Beam
®
System must be installed to close door.
For use only with residential sectional or one piece overhead garage doors.
®
®
Homelink
and Car2U
compatible.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
SAVE THIS MANUAL FOR FUTURE REFERENCE
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER
WAR N I N G
To reduce the risk of injury to persons or damage to property – Use this opener only with a one-piece or sectional door.
Genie, Genie logo, Intellicode, Safe-T-Beam, IntelliG, PowerMax, PowerLift, ChainMax and SilentMax are registered trademarks TriloG and GPower are trademarks of GMI Holdings, Inc., dba The Genie Company
Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation. ©The Genie Company 2012 PN#38209501582, 5/2012
38209501582

Advertisement

Table of Contents
loading

Summary of Contents for Genie SC 1500, TriloG 1200

  • Page 1 To reduce the risk of injury to persons or damage to property – Use this opener only with a one-piece or sectional door. Genie, Genie logo, Intellicode, Safe-T-Beam, IntelliG, PowerMax, PowerLift, ChainMax and SilentMax are registered trademarks TriloG and GPower are trademarks of GMI Holdings, Inc., dba The Genie Company Homelink is a registered trademark of Johnson Controls Technology Company.
  • Page 2: Table Of Contents

    Table of Contents Safety Information Safety Notifications .......... 3 TRANSMITTER COMPLIANCE STATEMENT Transmitters comply with all United States and Canadian legal Important Safety Instructions ......3 requirements as of the date of manufacture. No warranty is made that Infrared Protection Function ......3 they comply with all legal requirements of any other jurisdiction.
  • Page 3: Safety Information

    TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call The Genie® Company or your local Genie® Factory Authorized Dealer.
  • Page 4: Infrared Protection Function

    Begin here ONLY AFTER completing assembly and installation of the opener. Review the Assembly and Installation poster to ensure all steps have been performed. There are no assembly or installation steps included in this manual. Contact your Genie® Professional Dealer for an installation poster, if needed, or call 1-800-35GENIE. You may also visit www.geniecompany.com to download a PDF file.
  • Page 5: Required Programming

    – This program automatically sets how far your door travels up and down. Now that your Genie garage door opener is installed, you will want to 2. Remote Programs (Default menu) program the opener so that the door opens and closes properly and –...
  • Page 6: Travel Limits

    Required Programming TRAVEL LIMITS WA RN I NG Release down arrow button (-) and the long LED will begin flashing. people to avoid injury or damage to property. PROGRAM DO NOT operate this unit from wall console before LIMITS are set. Severe damage to the opener can occur. MUST be engaged to carriage BEFORE setting limits.
  • Page 7: Opening Garage Door (Up Limits)

    Required Programming Press and release the Program Set button (both Press and hold the up arrow button (+) until door is LEDs flash blue and go off). fully open, then release. PROGRAM PROGRAM PROGRAM – – HOLD The DOWN (closed) limit is programmed. Opening Garage Door (Up Limits) NOTE: Beginning with garage door closed is recommended but not necessary.
  • Page 8: Wall Console Overview

    Required Programming Required Programming WALL CONSOLE / Overview Series III Wall Consoles with Black Buttons MODEL AC SR3 THE GENIE COMPANY This opener has a serial FCC ID: B8Q AC SR3 Residential Door Operator number sticker in which Indicator Light IC: 2133A-CSD1D 120V.
  • Page 9: Force And Speed Control

    Required Programming Force and Speed Control Lay a 2” x 4” board flat under the center of the door opening. These controls are factory programmed and automatically set themselves when you use the Wall Console to open and close the garage door for the first time.
  • Page 10: Remotes/New Intellicode 2 Openers

    Required Programming REMOTES / New Intellicode 2 Openers NOTE: The following instructions are for the remote control Remove protective film for battery from remote. transmitters (“Remotes”) provided with this opener. This Remote is preset for use with the Intellicode 2 Access Security System. Refer to page 14 for additional information on Intellicode 1 and 2 Remotes and how to switch from Intellicode 2 to Intellicode 1.
  • Page 11 READY TO USE! NOTE: For Car2U and HomeLink, park the car outside the garage with the ignition key in the “Accessory” position. Follow the Car2U or HomeLink instruction to set the button in the car to Genie mode. PROGRAM PROGRAM IMPORTANT: Your HomeLink®...
  • Page 12: Optional Programming

    Optional Programming KEYPAD Press and hold the Program Set button on the Press and release the UP or DOWN arrow button a second time (both LEDs flash blue and turn off). Powerhead for 2 seconds (the round LED turns blue and then off, the long LED will begin flashing purple).
  • Page 13: Clearing Memory For Remotes

    Optional Programming CLEARING MEMORY FOR REMOTES To verify that the memory is cleared, press a remote button that was previously programmed to the Powerhead. Press the Program Set button on the Powerhead and hold 2 seconds, round LED comes ON. PROGRAM PROGRAM –...
  • Page 14: Intellicode 1 Remotes

    Intellicode 1. (Follow these same steps to change Intellicode 1 back to Intellicode 2.) If you have questions, see your Genie instructions for this Intellicode I NOTE: The button directly above the logo on the transmitter is preset model of opener.
  • Page 15: One Piece Doors

    One-Piece Doors ATTACHING DOOR BRACKET TO DOOR ATTACHING DOOR ARM TO DOOR BRACKET Using bracket, mark holes on door or frame and drill Screw drive models: 5/32" hole completely through door frame. One-Piece Doors will only accept a straight door arm. Curved door arm Curved door arm 3/8"-16 x 7/8"...
  • Page 16: Maintenance And Adjustments

    Maintenance and Adjustments If you have any questions, please do not hesitate to contact customer A. Contact Reverse Test service at: 1-800-35-GENIE or visit www.geniecompany.com See page 9. IMPORTANT SAFETY INSTRUCTIONS WAR NI N G WAR N IN G Use of any other wall control can cause unexpected operation of the door and loss of lighting feature.
  • Page 17: Corrective Maintenance

    Maintenance and Adjustments REGULAR MAINTENANCE (continued) Reset Open/Close Travel Limit Performing all eleven (11) Limits/Force setting steps (see pages 6-8) erases previous Limits/Force settings. (UP) position (pull release handle toward opener and let go) NOTE: The opener will not close the door automatically unless the Pull/release cord down and back towards opener and let go.
  • Page 18: Adjustment Guides

    Maintenance and Adjustments ADJUSTMENT GUIDES LED indicator colors: Blue Purple Powerhead LEDs C AU T I ON Force Level LONG LED ROUND LED Force Level 1 BLUE Door closing force is FACTORY set and requires no adjustment for normal operation. BLUE Force Level 2 NEVER adjust the force settings to compensate for damage,...
  • Page 19 Maintenance and Adjustments ADJUSTMENT GUIDES (continued) Blue Purple LED indicator colors: Powerhead LEDs Speed Settings (DC motors only) Speed Level LONG LED ROUND LED Speed settings are pre-programmed at the factory for the maximum speed. Speed settings should not need adjustment with this unit. High Medium PURPLE...
  • Page 20: Wiring Diagram

    Wiring Diagram Opener circuit wiring diagram. This wiring diagram is for reference only. WA R NI N G OPENING COVER MAY CAUSE ELECTRIC SHOCK. Disconnect power from opener prior to removing cover. POWER CORD SCREW DRIVE MOTOR CHAIN MOTOR CONNECTOR PRINTED CIRCUIT BOARD BLACK WHITE...
  • Page 21: Troubleshooting

    Troubleshooting OPERATION PROBLEM WHAT TO DO Opener does NOT run from wall console. ™ ™ See page 6 Opener runs, but door www.geniecompany.com does not move. Opener works from See page 17. wall console, but NOT See pages 10-11 from remote. Remote has less than See page 17 25 feet operating...
  • Page 22 Troubleshooting OPERATION (continued) PROBLEM WHAT TO DO Noisy operation. Door opener runs slow. POWERHEAD LEDS Powerhead LED Possible Problem Solution Round LED Long LED Normal operation. None required. Check power supply. No response from unit. Contact a trained door system technician. ON/RED/ ON/RED/ Limits NOT set properly.
  • Page 23: Warranty

    Claims under this warranty must be made promptly after discovery and within the applicable warranty period. To obtain warranty service, you must contact Genie® customer service and provide proof of the date and location of purchase and identification as the original purchaser. Call Genie® Customer Service toll free at 1-800-354-3643 to speak with a trained representative.
  • Page 24 Convenience, Security All in One Wireless Keypad Upgrade with style 37332R GK-R Perfect Stop Universal Wall Push Button Parking System NEW ACCESSORIES PRODUCTS Check out ; visit www.GenieCompany.com or call 1-800-35-GENIE. Also available at Home Improvement outlets and other retail/commercial locations nationwide.

Table of Contents