Mid-Travel Stop Position; Anti-Tailgate Enable; Motor Type Selection - Linear SWR Installation Manual

Swing gate operator
Hide thumbs Also See for SWR:
Table of Contents

Advertisement

Advanced Controller Programming (Cont.)

Mid-travel Stop Position

The Controller can be programmed so the gate will stop at a mid-travel
point instead of fully opening. This can be useful in installations where
a large gate, that takes a long time to open and close fully, only needs
to be opened partway to allow traffic to pass.
The factory default sets the Controller for full open operation. Alternately,
the Controller can be programmed to open for 1 to 99 seconds then
stop, before reaching the open limit.
When a Mid-travel Stop Position time has been programmed, the gate
will still fully open if the Fire Department input is triggered, if the OPEN
button is held down beyond the Mid-travel Stop Position, or a close
obstruction or reverse loop input is triggered.
✓ NOTE: The Mid‑travel Stop feature is disabled when dual gate
operation is enabled for paired units.

Anti-tailgate Enable

The factory default sets the Anti-tailgate Enable to OFF. With this setting,
during a gate cycle, after the shadow loop has been triggered by the
vehicle and then has cleared after the vehicle passes, the Auto Close
Timer or a CLOSE command is required to begin closing the gate.
If the Anti-tailgate Enable is set to ON, the gate will close immediately
as soon as the shadow loop has cleared. Any subsequent shadow loop
triggers while the gate is closing will stop the gate. When the shadow
loop clears, the gate will continue closing.

Motor Type Selection

The factory sets the default for the Controller to match the type of
motor in the operator. If required, change the motor selection option to
a different type of motor used in the operator. The options available are:
• AC Motor Only
• DC Motor Only with Mechanical Braking
• DC Motor with Electronic Soft Start/Stop
• 3 Phase AC Motor
• AC Motor with DC Motor Backup with Mechanical Braking
• AC Motor with DC Motor Backup with Electronic Soft Start/Stop
SWR • SWC • SWD Swing Gate Operator Installation Guide
FUNCTION
"MT"
MID-TRAVEL
STOP POSITION
FUNCTION
"AT"
ANTI-TAILGATE
ENABLE
FUNCTION
OPTIONS
"MO"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MOTOR TYPE
SELECTION
- 18 -
OPTIONS
MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)
SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
OPTIONS
ANTI-TAILGATE ENABLE OFF
GATE REQUIRES AUTO OR MANUAL CLOSE
ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AC MOTOR ONLY
DC MOTOR ONLY WITH BRAKING
DC MOTOR WITH SOFT START/STOP
3 PHASE AC MOTOR
AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH BRAKING
AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH SOFT START/STOP
NOTE: SELECTION
MUST MATCH
MOTOR BOARD!
227965 X28

Advertisement

Table of Contents
loading

This manual is also suitable for:

SwcSwdSwc-121

Table of Contents