Linear SWR Installation Manual
Linear SWR Installation Manual

Linear SWR Installation Manual

Swing gate operator
Hide thumbs Also See for SWR:
Table of Contents

Advertisement

Quick Links

SWR - SWC - SWD
Swing Gate Operator
Installation Guide
Operator models contained in this manual
conform to UL325 standard for use in
Class I, II, III, and IV applications
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
227965 X28
www.nortekcontrol.com

Advertisement

Table of Contents
loading

Summary of Contents for Linear SWR

  • Page 1 SWR - SWC - SWD Swing Gate Operator Installation Guide Operator models contained in this manual conform to UL325 standard for use in Class I, II, III, and IV applications USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com...
  • Page 2: Table Of Contents

    Model SWR Exploded View . . . . . . . . . . . . . . . . . .
  • Page 3: Pre-Installation Information

    Locate the gate such that persons will not come into contact with Miller Edge Models: RG-K-R, PG-K-R50 the vehicular gate during the entire path of travel of the vehicular gate. EMX Models: IRB-MON, IRB-RET - 1 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 4: Wiring Specifications

    2045 MODEL SWD POWER WIRING MAXIMUM DISTANCE (FEET) VOLTS & HP WIRE GAUGE SINGLE DUAL 1542 115 VOLTS 2452 1226 1/2-HP 3898 1949 6200 3100 - 2 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 5: Mounting Pad Installation

    CONCRETE OPERATOR PAD 3D VIEW "RIGHT-HAND" IN SOFT SOIL, POUR TWO 6" DIAMETER INSTALLATION 10" DEEP "LEGS" TO PREVENT ROTATION Figure 1. Mounting Pad Specifications - 3 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 6: Operator Preparation

    WELD THE GATE PLATE TO THE GATE (AN EXTRA SUPPORT WELDED TO THE GATE MAY BE REQUIRED) GATE PLATE LINK ASSEMBLY Figure 4. Gate Plate Installation - 4 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 7: Choosing Good Harmonics

    AND WELD 22" TYPICAL CAUTION! SET LENGTH CLAMP OR TACK WELD, AND WELD THEN TEST ARM ACTION BEFORE FULLY WELDING Figure 7. Setting Gate Arm Lengths - 5 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 8: Operator Setup

    Operator Setup LIFT UP ON TAB Controller Access The Controller in models SWR, SWC and SWD is hinged for access and can be removed without taking off the operator’s cover. It swings down for installation, programming, and troubleshooting access (see CONTROLLER SWINGS DOWN Figure 8).
  • Page 9: Limit Cam Rough Adjustment

    COUNTERCLOCKWISE the torque limiter. See page 13 for current sense setting. ONE FLAT THEN RE-TEST To adjust the torque limiter in models SWR and SWD: 1. Loosen the set screw on the torque limiter adjustment nut. TIGHTEN SET SCREW WHEN FINISHED 2.
  • Page 10: Controller Features

    OUTPUT INPUT TERMINALS TERMINALS REVERSE INPUT TERMINALS TERMINALS INPUT TERMINALS ALARM OPEN LOOP SHADOW/RESET LOOP OUTPUT INPUT TERMINALS INPUT TERMINALS TERMINALS Figure 12. Controller Features - 8 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 11: Indicator Descriptions

    "AD" "MD" PROGRAMMING PRESSURE MODE STOP POSITION TRANSMITTERS SHADOW LOOP ANTI-TAILGATE RESET TO MAXIMUM "RT" "SP" "AT" "CL" OPEN INHIBIT ENABLE FACTORY DEFAULTS RUN TIMER - 9 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 12: Terminal Descriptions

    24 VOLT SOLAR PANEL FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING. 24 VOLT BATTERY FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS. - 10 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 13: Operator Accessory Connections

    GATE EDGE SENSOR FOR REVERSE TWO-CHANNEL RADIO RECEIVER WARNING STROBE OR AUDIBLE SOUNDER CHANNEL #1 WIRELESS GATE EDGE SENSOR OPEN/CLOSE TRANSMITTER Figure 13. Operator Accessory Connections - 11 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 14: Basic Controller Programming

    1 TO 59 SECONDS DOWN TO CYCLE THROUGH OPTIONS SET TIMER VALUE PRESS ENTER TO 1 TO 9 MINUTES SELECT AN OPTION AUTO CLOSE TIMER - 12 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 15: Run Alarm And Pre-Start Alarm

    (50-75 lbs.) will activate a reversal should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption. - 13 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 16: Advanced Controller Programming

    PRESS UP OR DELAYED OPEN DOWN TO CYCLE THROUGH OPTIONS SETS THIS OPERATOR FOR PRESS ENTER TO DELAYED CLOSE SELECT AN OPTION STAGGER DUAL GATES MODE ONLY - 14 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 17: Stagger Delay Time

    THROUGH OPTIONS CLOSE BUTTON SET FOR PRESS ENTER TO CONSTANT PRESSURE SELECT AN OPTION CONSTANT OPEN AND CLOSE BUTTONS BOTH SET FOR CONSTANT PRESSURE PRESSURE MODE - 15 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 18: Shadow Loop Open Prevention

    When AC power is restored, the operator will resume normal operation. ✓ NOTE: This function will only be displayed in Model SWD operators. - 16 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 19: Soft Start/Stop Duration

    Cycle Count. RESETS THE MAINTENANCE ALERT PRESS ENTER TO INDICATOR AND SETS THE MAINTENANCE SELECT AN OPTION ALERT COUNT TO ZERO MAINTENANCE ALERT TRIGGER - 17 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 20: Mid-Travel Stop Position

    DC MOTOR BACKUP WITH SOFT START/STOP • AC Motor with DC Motor Backup with Mechanical Braking • AC Motor with DC Motor Backup with Electronic Soft Start/Stop - 18 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 21: Radio Enable

    PRESS ENTER) OR MOTOR TYPE. RESET TO ERASE MGT THE DISPLAY WILL SHOW "DELETE ALL" AND THE CONTROLLER RETURNS TO PROGRAMMING MODE FACTORY DEFAULTS TRANSMITTERS - 19 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 22: Loop Layout Illustration

    Loop Layout Illustration - 20 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 23: Safety Edge Layout Illustration

    Safety Edge Layout Illustration - 21 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 24: Photoeye Installation Illustration

    Photoeye Installation Illustration - 22 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 25: Dual Gate Installations

    SHIELD Open Loop Functions the same as the OPEN button. Reverse Loop Functions the same as the reverse input. Figure 14. COMM LINK Wiring - 23 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 26: Shadow/Reset Loop

    FAST BEEPS DURING PRESTART, CLEARS WHEN MGT CONDITION (TAMPER, LOW BATTERY, MISSING FAST BEEP RUN ALARM, CHIRP CLEARS HOURLY STATUS) EVERY 5 SECONDS AT IDLE - 24 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 27: Troubleshooting

    5. Specify name and address of person or company to whom parts are to be shipped. 6. Specify name and address of person or company to whom invoice is to be sent - 25 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 28: Model Swr Exploded View

    Sprocket, 40-B-36, 1” bore 2200-673 #40 Chain, 21 Links 2200-006 #40 Master Link 2100-1748 Limit Cam 2200-015 Shaft Collar, 1” diameter, 9/16 LTB 2500-2347 Limit Switch - 26 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 29: Model Swc Exploded View

    2200-958 Sprocket, 40-B-14, 1-1/8” bore (for 1 HP) 2100-2041 Operator Base Plate 2100-2020-PLT Drive Shaft 2200-015 Shaft Collar, 1” diameter, 9/16 LTB 2100-519-PLT Sleeve Spacer - 27 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 30: Model Swd Exploded View

    Friction Disc Pair for 5” Torque Limiter 2120-483 Post Mounting Kit 2200-782 Bushing for 5” Torque Limiter 2100-2041 Operator Base Plate 2200-583 Sprocket, 40-A-36, 1” Bore - 28 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 31: Swr, Swc, Swd Gate Arm Assembly Exploded View

    Nylon Washer 2400-508 Hex Head Screw, grade 8, 1/2-13 x 3-3/4” 2400-507 Nylon Insert Locknut, grade 8, 1/2-13 2400-510 Shoulder Bolt for Rain Cap, 1/4-20 - 29 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 32: Model Swd Maintenance

    THE HOLDER (IT ONLY REPEAT INSPECTION WITH THE BRUSH FITS IN ONE WAY) ON THE OTHER SIDE OF THE MOTOR Figure 15. Replacing DC Motor Brushes - 30 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 33: Preventative Maintenance

    . If the gate does bind, adjust or fix as required . Failure to keep the gate in good working condition will have adverse effects on the operator . - 31 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 34: Gate Operator Installation Checklist

    By signing this installation checklist, I/we hereby certify that each item listed and checked above has been covered by the installer and is clearly understood by the customer. Customer’s Signature Date Installer’s Signature Date - 32 - SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...
  • Page 35: Notes

    Notes SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 X28...

This manual is also suitable for:

SwcSwdSwc-121

Table of Contents