Advanced Controller Programming (Cont.)

Reset Cycle Count

The Controller counts of the number of times the operator has been
cycled full open and close. The cycle count can be displayed. The display
will scroll the cycle count number, fl ashing two digits at a time from left
to right.
To reset the Cycle Count, press and hold the ENTER button for 2 seconds
while the Cycle Count is displayed.
If the Maintenance Alert has been triggered, resetting the Cycle Count
will also reset the Maintenance Alert indicator.

Maintenance Alert Trigger

The Controller has a MAINT ALERT indicator that can be programmed
to light when the number of activations exceeds a set number of cycles.
The factory default sets the Maintenance Alert Trigger to 10,000 cycles.
The Maintenance Alert Trigger can be programmed for 5, 10, 15, or 25
thousand cycles.
The Maintenance Cycle Count can be reset independently from the
operator's absolute Cycle Count.

Mid-travel Stop Position

The Controller can be programmed so the gate will stop at a mid-travel
point instead of fully opening. This can be useful in installations where a
large gate, that takes a long time to open and close fully, only needs to
be opened partway to allow traffi c to pass.
The factory default sets the Controller for full open operation. Alternately,
the Controller can be programmed to open for 1 to 99 seconds then stop,
before reaching the open limit.
When a Mid-travel Stop Position time has been programmed, the gate
will still fully open if the Fire Department input is triggered, if the OPEN
button is held down beyond the Mid-travel Stop Position, or a close
obstruction or reverse loop input is triggered.
✓ NOTE: The Mid-travel Stop feature is disabled when dual gate
operation is enabled for paired units.

Anti-tailgate Enable

The factory default sets the Anti-tailgate Enable to OFF. With this setting,
during a gate cycle, after the shadow loop has been triggered by the
vehicle and then has cleared after the vehicle passes, the Auto Close
Timer or a CLOSE command is required to begin closing the gate.
If the Anti-tailgate Enable is set to ON, the gate will close immediately
as soon as the shadow loop has cleared. Any subsequent shadow loop
triggers while the gate is closing will stop the gate. When the shadow loop
clears, the gate will continue closing.

Radio Enable

The Controller contains a built-in MegaCode
activation from up to 40 access control transmitters and two Model MGT
(gate edge) transmitters. The factory default enables the internal radio
receiver. Alternately, the internal receiver can be disabled.

Antenna Installation

The Controller is supplied with a local whip antenna installed. If using a
remote antenna, remove the whip antenna and connect coax cable from
the antenna to the ANTENNA connector.
VS-GSWG Swing Gate Operator Installation Guide
radio receiver to allow
®
- 16 -
FUNCTION
PRESS ENTER TO START THE CYCLE COUNT DISPLAY
"CT"
1ST DISPLAY
2ND DISPLAY
EXAMPLE ABOVE SHOWS 10,420 CYCLES
NOTE: PRESS ENTER FOR 2 SECONDS
RESET CYCLE
WHILE THE "CT" FUNCTION IS DISPLAYED
COUNT
TO RESET THE CYCLE COUNT TO ZERO
FUNCTION
OPTIONS
"MA"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MAINTENANCE
ALERT TRIGGER
FUNCTION
OPTIONS
"MT"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
MID-TRAVEL
PRESS ENTER TO
SELECT AN OPTION
STOP POSITION
FUNCTION
OPTIONS
"AT"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
ANTI-TAILGATE
PRESS ENTER TO
SELECT AN OPTION
ENABLE
FUNCTION
OPTIONS
"RA"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
RADIO
PRESS ENTER TO
SELECT AN OPTION
ENABLE
3RD DISPLAY
4TH DISPLAY
DECIMAL POINT LIT
ON 4TH DISPLAY
DISABLES THE MAINTENANCE ALERT
FUNCTION
SETS THIS MAINTENANCE ALERT TRIGGER
FOR 5, 10, 15, OR 25 THOUSAND CYCLES
RESETS THE MAINTENANCE ALERT
INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO
MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)
SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS
ANTI-TAILGATE ENABLE OFF
GATE REQUIRES AUTO OR MANUAL CLOSE
ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS
INTERNAL RADIO RECEIVER DISABLED
INTERNAL RADIO RECEIVER ENABLED
P1250 Revision X6 7-8-2011