Page 1
VS-GSWG Swing Gate Operator Installation Guide Operator models contained in this manual conform to UL325 standard for use in Class I, II, III, and IV applications USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340...
2. Read the yellow “Safety Instructions” brochure enclosed with the packet of information. If any pages are missing or are unreadable, or you do not have the safety instructions, please call Linear at 1-800-421-1587 to request additional copies. 3. ALL ELECTRICAL CONNECTIONS TO THE POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES.
Twisted Pair Shielded Cable (or equivalent) only – P/N 2500-1982, per foot). See Page 21 for details of this connection. Note: The shield wire should be connected in both the operators. VS-GSWG Swing Gate Operator Installation Guide MODEL VS-GSWG SINGLE PHASE POWER WIRING MAXIMUM DISTANCE (FEET) VOLTS &...
✓ NOTE: If non-standard mounting is necessary, consult the factory. VS-GSWG Swing Gate Operator Installation Guide The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening.
✓ NOTE: Observe the way the chain threads around the sprockets for left-hand or right-hand installations. Refer to Figure 4. 6. Adjust for taut chain tension but do not overtighten. 7. Replace the arm assembly cover. VS-GSWG Swing Gate Operator Installation Guide GEAR REDUCER INSTALL THE VENT PLUG...
AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES AC Power Connection All Linear gate operators are supplied with a power disconnect switch to turn on and off the power available to the operator. Following wiring specifi cations on Page 2, incoming power should be brought into the operator and connected to the labeled pigtails from the disconnect box.
Care must be taken not to adjust too close to the center as the limit nut may travel past the switch and start accelerating at the end of the cycle. VS-GSWG Swing Gate Operator Installation Guide RIGHT-HAND INSTALLATION...
✓ NOTE: The open and close current sensing may need to be adjusted before performing the following two steps. See Page 13. To adjust the torque limiter in a Model VS-GSWG: 1. Loosen the set screw on the adjustment nut.
MAXIMUM CLOSE "CC" CURRENT ADVANCED "AD" PROGRAMMING VS-GSWG Swing Gate Operator Installation Guide INDICATION WHEN LIT DURING NORMAL OPERATION LOW VOLTAGE AC POWER IS PRESENT LOW VOLTAGE DC POWER IS PRESENT OPEN SIGNAL PRESENT FROM THE INTERNAL RECEIVER OR AN EXTERNAL DEVICE...
AUX RELAY N.C. 24 VOLT SOLAR PANEL 24 VOLT BATTERY VS-GSWG Swing Gate Operator Installation Guide FUNCTION FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON.
1 to 59 seconds and from 1 to 9 minutes. When the Auto Close Timer is set, after opening, the gate will wait for the length of the Auto Close Timer then close automatically. VS-GSWG Swing Gate Operator Installation Guide DOWN PRESS DOWN AND UP...
Using the + and - buttons, set the programmed range number so that a minimal force (50-75 lbs.) will activate a reversal should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption. VS-GSWG Swing Gate Operator Installation Guide FUNCTION OPTIONS "RP"...
Stagger Mode. The Stagger Delay Time can be set from 1-99 seconds. ✓ NOTE: This function will only be displayed if dual gate operation is selected. VS-GSWG Swing Gate Operator Installation Guide FUNCTION OPTIONS "AD"...
Brake Delay Time This function is displayed, but only used in operators with mechanical brakes. The Model VS-GSWG does not have a mechanical brake. The factory default sets the Brake Delay to no delay (0 seconds). Heavy gates may require delayed braking to allow the gate to slow down before stopping it.
The Controller is supplied with a local whip antenna installed. If using a remote antenna, remove the whip antenna and connect coax cable from the antenna to the ANTENNA connector. VS-GSWG Swing Gate Operator Installation Guide FUNCTION "CT" RESET CYCLE...
STORED IN MEMORY. NOTE: THIS FUNCTION WILL NOT ERASE TRANSMITTERS, CURRENT SENSE VALUES, OR MOTOR TYPE. RESET TO FACTORY DEFAULTS VS-GSWG Swing Gate Operator Installation Guide FUNCTION PRESS ENTER (ONCE FOR EACH TRANSMITTER, ENTER UP TO 40 TRANSMITTERS TOTAL) "TL"...
CONNECT SHIELD WIRE AT BOTH ENDS SHIELD Figure 13. COMM LINK Wiring VS-GSWG Swing Gate Operator Installation Guide Optional In-Cabinet Heater The operator can be ordered with an optional cold weather package that includes an in-cabinet heater to keep the drive train and electronics warm in cold environments.
If the auto close timer is set, when the close obstruction input is cleared, the gate will close when the auto close timer expires. VS-GSWG Swing Gate Operator Installation Guide Reverse Input If the reverse input is triggered while the gate is closing, the gate will reverse to the full open position.
Maximum Run Time has been exceeded, the sounder will beep twice every fi ve seconds. The next operation of the gate will clear the indication. VS-GSWG Swing Gate Operator Installation Guide CONTROLLER ERROR CAUSES AND INDICATIONS ERROR CAUSE...
A. Check the setscrews in limit cams for tightness. Replace if necessary. Contact your local Linear dealer or distributor to order parts. 1. Supply the model number and serial number of your operator. 2. Specify the quantity of pieces needed and order by part number and name of part.
Always disconnect power from operator before servicing. Keep clear of gate during operation. General Linear gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance. To ensure that a unit is ready for operation at all times, and to preclude serious damage or failure, inspect the unit systematically.
Page 29
REF. # VS-GSWG Swing Gate Operator Installation Guide MODEL SWG MECHANICAL PARTS LIST PART # DESCRIPTION 2120-361 Complete Enclosure Assembly with Door 2110-067 Enclosure Assembly without Door 2120-362 Enclosure Door and Lock Assembly 2110-643 Snap Lock Assembly only 2110-161 Mounting Panel Assembly...
TARGET SPEED SECOND SPEED MIN SPEED AUTO RESET TERM 3 FUNC TERM 4 FUNC VS-GSWG Swing Gate Operator Installation Guide NOTE: L200 model must have this switch in the UP (SR) position. List of parameters set at factory RECOMMENDED FUNCTION...
By signing this installation checklist, I/we hereby certify that each item listed and checked above has been covered by the installer and is clearly understood by the customer. Customer’s Signature Installer’s Signature VS-GSWG Swing Gate Operator Installation Guide Date Date - 32 -...