Linear HSLG Series Installation Manual
Linear HSLG Series Installation Manual

Linear HSLG Series Installation Manual

Slide gate operator
Hide thumbs Also See for HSLG Series:

Advertisement

Quick Links

HSLG
Slide Gate Operator
Installation Guide
Operator models contained in this manual
conform to UL325 standard for use in
Class I, II, III, and IV applications
www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com

Advertisement

Table of Contents
loading

Summary of Contents for Linear HSLG Series

  • Page 1 HSLG Slide Gate Operator Installation Guide Operator models contained in this manual conform to UL325 standard for use in Class I, II, III, and IV applications www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 2 Reverse Loop ..........26 LINEAR SLIDE GATE Shadow/reset Loop .
  • Page 3: Pre-Installation Information

    If any pages are missing or are unreadable, or you do not A vehicular gate operator intended for use in an industrial location or have the safety instructions, please call Linear at 1-800-333-1717 to building such as a factory or loading dock area or other location not request additional copies.
  • Page 4: Wiring Specifications

    Wiring Specifications MODEL HSLG SINGLE PHASE POWER WIRING MAXIMUM DISTANCE (FEET) VOLTS & HP WIRE GAUGE Refer to the following steps for details on power and accessory wiring SINGLE DUAL for the operator. 115 VOLTS WARNING 1/2-HP ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE AND 1430 THE OPERATOR MUST BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL...
  • Page 5: Mounting Pad Installation

    Pedestrians must be supplied with a separate access The posts support the operator and prevent it from moving during opening. The pedestrian access opening shall be designed to operation. For optional pad mounting instructions, see Linear drawing promote pedestrian usage. Locate the gate such that persons #2700-360.
  • Page 6: Gate Bracket And Chain Assembly

    Gate Bracket and Chain Assembly END OF GATE PIPE SHOWN ✓ NOTE: The item numbers shown in these illustrations REFERENCE ONLY are for reference only. For the actual part numbers, refer to the parts lists in the rear of this manual. Assemble a gate bracket (1) to the front edge of the gate, using two U-bolts (2), and mounting hardware (3).
  • Page 7 Figure 6. Controller Access the spring-loaded shifter lever to snap back into the engaged position. AC Power Connection TO MANUALLY MOVE THE GATE, All Linear gate operators are supplied with a power disconnect switch PULL SHIFTER LEVER TO WARNING DISENGAGE THE DRIVE TRAIN...
  • Page 8 Operator Setup (Cont.) RIGHT-HAND INSTALLATION LEFT-HAND INSTALLATION CLOSE LIMIT OPEN LIMIT OPEN LIMIT CLOSE LIMIT LIMIT Open and Close Limit Adjustment SWITCHES The limit nuts are not preset at the factory and must be adjusted for the gate in each installation. The limit switches are activated by two threaded nylon rotary limit nuts which are attached to a threaded limit shaft driven by a chain and sprockets from the main drive shaft.
  • Page 9: Controller Features

    Controller Features WHIP ANTENNA ANTENNA CONNECTOR OPERATION AND POWER PROGRAMMING OPERATION INDICATORS INDICATORS BUTTONS DISPLAY PROGRAMMING SOLAR BUTTONS PANEL TERMINALS INPUT POWER MOTOR TERMINALS BOARD COVER ACCESSORY POWER BATTERY TERMINALS CONTROLLER TERMINALS RESET BUTTON PLUG-IN TERMINALS LOOP PRIMARY/ DETECTOR SECONDARY CONNECTORS COMM LINK TERMINALS...
  • Page 10: Indicator Descriptions

    Indicator Descriptions INDICATOR DEFINITION INDICATION WHEN LIT INDICATION WHEN LIT DURING NORMAL OPERATION DURING PROGRAMMING OPERATION PROGRAMMING 24 VOLT INPUT POWER LOW VOLTAGE AC POWER IS PRESENT 24 VOLT DC LOW VOLTAGE DC POWER IS PRESENT ACCY POWER OPEN SIGNAL PRESENT FROM THE INTERNAL OPEN RECEIVER OR AN EXTERNAL DEVICE CONNECTED TO THE OPEN INPUT TERMINAL...
  • Page 11: Terminal Descriptions

    Terminal Descriptions TERMINAL GROUP FUNCTION AC N FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR 24 24 VOLT INPUT VDC FROM CONTINUOUS DUTY DC SUPPLY. DC - ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) DC + RESET RESET BUTTON FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON.
  • Page 12: Operator Accessory Connections

    Operator Accessory Connections 3-BUTTON STATION TELEPHONE ENTRY PHOTOEYE FOR REVERSE KEYPAD PHOTOEYE FOR CLOSE OBSTRUCTION (B1) KEYSWITCH SOLENOID LOCK FIRE ACCESS SWITCH EXTERNAL POWER PHOTOEYE FOR OPEN OBSTRUCTION (B1) SINGLE-CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE (B2) WARNING STROBE OR AUDIBLE SOUNDER WIRELESS GATE EDGE SENSOR TRANSMITTER Figure 13.
  • Page 13: Basic Controller Programming

    Basic Controller Programming Programming Overview PROGRAM The Controller can be programmed with various options for the operator. INDICATOR The programming fields are defined as “functions” that have “options”. DOWN To make setup easier for the installer, the Controller’s programming is divided into two groups: basic and advanced.
  • Page 14 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm FUNCTION OPTIONS RUN ALARM OFF The factory default is Run Alarm on and a 3-second Pre-start Alarm. "RP" PRE-START ALARM OFF The operator’s beeper will sound 3 seconds before the operator starts. The options are: RUN ALARM ON PRESS UP OR...
  • Page 15 Obstruction detection type – b1, b2 FUNCTION OPTIONS B1 is a non-contact sensor such as a photo eye. B2 is a contact sensor "OT" FOR NON-CONTACT SENSOR such as an edge. This setting affects behavior in the closed direction obstruction detection. If a B2 detector is used, the operator will only allow an input 2 times to continue automatic closing until a closed limit FOR CONTACT SENSOR switch is successfully made.
  • Page 16: Advanced Controller Programming

    Advanced Controller Programming Entering Advanced Programming Mode FUNCTION OPTIONS ADVANCED PROGRAMMING FUNCTIONS To access and program the Advanced Programming functions, for each "AD" WILL NOT BE DISPLAYED programming session, Advanced Programming must be enabled. After exiting programming, the Advanced Programming functions ADVANCED PROGRAMMING OPTIONS WILL BE DISPLAYED will be available on the programming display during the next...
  • Page 17 Advanced Controller Programming (Cont.) FUNCTION OPTIONS "AR" AUXILIARY RELAY DISABLED Auxiliary Relay Mode The Auxiliary Relay has normally open and normally closed contacts. AUXILIARY RELAY USED FOR MAGLOCK CONTROL The factory setting disables the Auxiliary Relay. The relay can be set for: PRESS UP OR DOWN TO CYCLE AUXILIARY RELAY USED FOR...
  • Page 18 Advanced Controller Programming (Cont.) Reset Cycle Count FUNCTION PRESS ENTER TO START THE CYCLE COUNT DISPLAY The Controller counts of the number of times the operator has been "CT" cycled full open and close. The cycle count can be displayed. The 1ST DISPLAY 2ND DISPLAY 3RD DISPLAY...
  • Page 19 Advanced Controller Programming (Cont.) Radio Transmitter Learn FUNCTION PRESS ENTER (ONCE FOR EACH TRANSMITTER, ENTER UP TO 40 TRANSMITTERS TOTAL) The Controller’s built-in MegaCode radio receiver can store the IDs of ® "TL" up to 40 transmitters. Refer to the figure for the steps required to learn "TL"...
  • Page 20 FUNCTION OPTIONS NOTE: SELECTION AC MOTOR ONLY MUST MATCH Motor Type Selection "MO" MOTOR BOARD! DO NOT SELECT The factory sets the default for the Controller to match the type of NOT USED IN THIS MODEL PRESS UP OR motor in the operator. If required, change the motor selection option to DO NOT SELECT DOWN TO CYCLE NOT USED IN THIS MODEL...
  • Page 21: Loop Layout Illustration

    Loop Layout Illustration - 19 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 22: Safety Edge Layout Illustration

    Safety Edge Layout Illustration #1 - 20 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 23 Safety Edge Layout Illustration #2 - 21 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 24: Photoeye Installation Illustration

    Photoeye Installation Illustration - 22 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 25: Picket Gate Installation

    Picket Gate Installation - 23 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 26: Track Gate Installation

    Track Gate Installation - 24 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 27: Dual Gate Installations

    Dual Gate Installations Two operators can be used in dual gate installations. The operators DUAL GATE communicate with each other through the 3-wire COMM LINK OPERATOR #1 COMM LINK terminals. SHIELD WIRING When one operator activates, the COMM LINK connection signals the other operator to activate.
  • Page 28: Operation Indications

    Gate Operation Reverse Input If the reverse input is triggered while the gate is closing, the gate will Open Button reverse to the full open position. If the Auto Close Timer is set, when the Opens the gate. If the Controller is programmed to stop opening the reverse input is cleared, the gate will close when the Auto Close Timer gate at mid-travel, a constant press of the OPEN button will override the expires.
  • Page 29: Error Indications

    Error Indications CONTROLLER ERROR CAUSES AND INDICATIONS During abnormal operation, the Controller’s displays and beeper will ERROR CAUSE ERROR INDICATION HOW TO CLEAR indicate the error condition that has occurred. TWO SAFETY REVERSALS En 00, CONTINUOUS (ON SINGLE GATE OR ON ALARM BEEPER, GATE PRESS STOP BUTTON Entrapment...
  • Page 30: Troubleshooting

    How to Order Replacement Parts Use the part numbers listed on the following pages. Contact your local Linear dealer or distributor to order parts. 1. Supply the model number and serial number of your operator. 2. Specify the quantity of pieces needed and order by part number and name of part.
  • Page 31: Preventative Maintenance

    10. Inspect the installation area. Are all the warning signs intact and visible? If they are missing or need replacing, contact Linear. Be sure there are no control stations mounted within reach of the gate. Review safety literature with the customer and advise them to remove any such stations found.
  • Page 32: Model Hslg Exploded View

    Model HSLG Exploded View - 30 - HSLG Slide Gate Operator Installation Guide P1220 X14 www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com...
  • Page 33 2500-2307 1/2 HP, 115 VAC, 1 Phase MODEL HSLG MECHANICAL PARTS LIST 2500-2308 1/2 HP, 208/230 VAC, 1 Phase REF. # PART # DESCRIPTION 2500-2309 3/4 HP, 115 VAC, 1 Phase Intermediate Shaft Assembly 2110-240 2500-2310 3/4 HP, 208/230 VAC, 1 Phase 2100-765 Pulley Shaft 2500-2311...
  • Page 34: Single Phase Controller Parts List

    Single Phase Controller Parts List 115V MODELS ONLY SINGLE PHASE CONTROLLER MECHANICAL PARTS LIST REF. # PART # DESCRIPTION 2100-1756 Mounting Plate 620-101293 Apex Module 2510-422 115V Power Box Assembly 2510-430 208/230V Power Box Assembly 2100-2143 Power Box Mounting Strap 2300-1025 Apex Plastic Cover 2510-423...
  • Page 35: Three Phase Controller Parts List

    Three Phase Controller Parts List THREE PHASE CONTROLLER MECHANICAL PARTS LIST REF. # PART # DESCRIPTION 2520-530 Control Box Assembly (Complete) 208/230V 2520-531 Control Box Assembly (Complete) 460V 2110-840 Control Box Assembly (Box only) 2100-582 Cover 620-101293 Apex Module 2500-1980 Motor Board 2500-034 Power Switch...
  • Page 36: Gate Operator Installation Checklist

    Gate Operator Installation Checklist INSTALLER CUSTOMER ❑ ❑ The gate has been checked to make sure it is level and moves freely in both directions. ❑ ❑ Potential pinch areas have been guarded so as to be inaccessible OR have contact and/or non-contact obstruction sensing devices installed.

This manual is also suitable for:

Hslg-443Hslg-123Hslg-111Vs-gslg-111Hslg-421Hslg-411

Table of Contents