Shadow/Reset Loop

Holds the gate fully open or fully closed while triggered. If open, the gate
closes immediately when cleared if Anti-tailgate is enabled.

Operation Indications

During normal operation, the Controller's displays will indicate current
operating conditions and status.

Power-up Display

When the Controller powers up, dashes will show on the display, then
the firmware version number, then the gate type (SL for slide and swing
gates).
Exiting programming restarts the Controller. The power-up display will
show upon the restart.

Idle Condition

While the Controller is idling, waiting for a command, the display will
show circulating dashes.
For DC models only - Clockwise : Batteries discharging, Counterclockwise
: Batteries charging.

Last Gate Position/Condition

When the gate moves or stops, the display will show the status for up
to one minute.
St
• Stop is displayed as
• Full Close is displayed as
• Full Open is displayed as
• Entrapment is displayed as

Pre-start Delay

During the pre-start delay, the display will countdown the number of
seconds remaining before the operator starts.

Reverse Delay

If the gate travel direction is reversed from a user activation or reversing
device, and a reverse delay is set, the display will count down the delay time
in seconds before the operator restarts.

Run Timer

While the gate is opening or closing, the number of seconds running
time is displayed.

Error Indications

During abnormal operation, the Controller's displays and beeper will
indicate the error condition that has occurred.

Entrapment

WARNING
The Stop and/or Reset button must be located in the line-of-sight
of the gate. Activation of the reset control shall not cause the
operator to start.
If an entrapment condition occurs detected by two repeated open or
close obstruction triggers, the Controller will lock the operator out. The
beeper will sound constantly and the gate will not operate. To reset the
Controller press the STOP button or press the RESET button on the
operator's cover.
SWR • SWC • SWD Swing Gate Operator Installation Guide
FC
FO
En

COMM LINK Connection Failure

In dual gate installations, if there is a connection failure between the
two operators, the COMM LINK indicator will blink once a second.
During this condition the gate will not operate, except if triggered by the
FIRE DEPT input, which functions normally.

MGT Obstacle Transmitter Trouble

If any MGT transmitters are used with the operator, their supervision
feature will alert the Controller if there is any trouble with the transmitter.
MGT transmitters send hourly status reports and will send low battery
reports when the transmitter has a low battery. The MGT transmitters
also have a tamper detection switch that will trigger when their case
is opened.
When the Controller detects a low transmitter battery, a tamper signal,
or missing transmitter status reports, the gate will still operate normally,
but the beeper will change as follows:
• The Pre-start Alarm will beep twice as fast.
• The Run Alarm will beep twice as fast and continue for five minutes
after the gate stops.
• The sounder will "chirp" every five seconds when the gate is idle.
Correct the trouble (close case, replace battery, or replace transmitter)
to clear the obstacle transmitter trouble indications.

Maximum Run Time Exceeded

If the Maximum Run Time is exceeded, the Controller stops the operator
the same as if a double obstacle has occurred in an entrapment
condition. The entrapment alarm sounds constantly, and is cleared by
pressing the STOP button or the RESET button on the cover. After the
STOP or RESET button is pressed, because the Maximum Run Time has
been exceeded, the sounder will beep twice every five seconds. The
next operation of the gate will clear the indication.
CONTROLLER ERROR CAUSES AND INDICATIONS
ERROR CAUSE
TWO SAFETY REVERSALS (ON
SINGLE GATE OR ON EITHER
DUAL GATE)
MAXIMUM RUN TIMER EXCEEDED
ON OPENING
MAXIMUM RUN TIMER EXCEEDED
ON CLOSING
COMM LINK FAILURE
GATE FULL OPEN RESULTING FROM
FIRE DEPT INPUT
FAIL SAFE OR FAIL SECURE
BECAUSE OF BATTERY VOLTAGE
DROP BELOW 21.6 VDC DUE TO AC
POWER LOSS
OTHER CONTROLLER IN
ENTRAPMENT (DUAL GATE)
LOW AC VOLTAGE AT CONTROLLER
INPUT TRIGGERED DURING
ENTRAPMENT LOCKOUT
COMPATIBILITY PROBLEM
EEPROM PROBLEM
DC MOTOR MISMATCH
MOTOR FAILURE
AC POWER LOSS IN OPEN OR
CLOSE IMMEDIATE POWER FAIL
MODE
MAXIMUM RUN TIMER EXCEEDED
AFTER AC POWER LOSS
MGT SUPERVISORY CONDITION
(TAMPER, LOW BATTERY, MISSING
HOURLY STATUS)
- 24 -
ERROR INDICATION
HOW TO CLEAR
En 00, CONTINUOUS ALARM
PRESS STOP BUTTON
BEEPER, GATE DISABLED
PRESS STOP BUTTON, CLEARS
En 01, AND MAX RUN LED,
CONTINUOUS ALARM, THEN
CONTINUOUS ALARM BEEPER,
DOUBLE BEEP EVERY 5 SECONDS
GATE DISABLED
UNTIL NEXT OPERATION
PRESS STOP BUTTON, CLEARS
En 02, AND MAX RUN LED,
CONTINUOUS ALARM, THEN
CONTINUOUS ALARM BEEPER,
DOUBLE BEEP EVERY 5 SECONDS
GATE DISABLED
UNTIL NEXT OPERATION
En 03, AND COMM LINK LED,
CONTINUOUS ALARM BEEPER
PRESS STOP BUTTON, CLEARS
FOR 1 MINUTE, GATE DISABLED
CONTINUOUS ALARM
(EXCEPT FOR FIRE DEPT INPUT)
En 04, GATE DISABLED
PRESS STOP BUTTON
BATTERY VOLTAGE MUST RISE
En 05, GATE DISABLED
ABOVE 24 VDC
CLEAR ENTRAPMENT ON OTHER
En 06, GATE DISABLED
CONTROLLER (PRESS STOP)
RESTORE AC POWER TO NORMAL
En 07, GATE DISABLED
LEVEL
En 08, GATE DISABLED
PRESS STOP BUTTON
UPDATE FIRMWARE AND RESET
En 09, GATE DISABLED
BOTH PAIRED CONTROLLERS
En 10, GATE DISABLED
TRY RESET, CALL TECH. SUPPORT
REPROGRAM MOTOR TYPE OR
CHANGE DC MOTOR BOARD, NEXT
En 11, GATE DISABLED
GATE MOVEMENT WILL RETRY DC
MOTOR CHECK
En 12, GATE DISABLED
CALL TECH. SUPPORT
En 13
REAPPLY AC POWER
BATTERY VOLTAGE MUST RISE
En 14
ABOVE 24 VOLTS
FAST BEEPS DURING PRESTART,
CLEARS WHEN MGT CONDITION
FAST BEEP RUN ALARM, CHIRP
CLEARS
EVERY 5 SECONDS AT IDLE
227965 X28