Programming Console Operations
66
If a mistake was made inputting the instruction, press the Up Arrow Key to
return to the previous program address and input the instruction again. The
mistaken instruction will be overwritten
6. Input the second instruction and operand. (In this case it isn't necessary to
enter the timer number, because it's 000.) Press the WRITE Key to write the
instruction to Program Memory.
Timer number
WRITE
TIM
7. Input the second operand (123 to specify 12.3 seconds) and press the
WRITE Key. The next program address will be displayed.
B
C
D
1
2
3
WRITE
If a mistake was made inputting the operand, press the Up Arrow Key to
return to display the mistaken operand, press the CONT/# Key and 123
again. The mistaken operand will be overwritten.
Note Counters are input in the same basic way as timers except the CNT
Key is pressed instead of the TIM Key.
8. Input the third instruction and its operands. First input the instruction by
pressing the FUN Key and then the function code (21 in this case).
C
2
FUN
Note To input a differentiated instruction, press the NOT Key after entering
the function code. The "@" symbol will be displayed next to differen-
tiated instructions. Press the NOT Key again to change back the
instruction back to a non-differentiated instruction. The "@" symbol
will disappear. To change an instruction after it has been entered,
simply scroll through the program until the desired instruction is dis-
played and press the NOT Key. The "@" symbol should be displayed
next to the instruction.
9. Press the WRITE Key to write the instruction to Program Memory. The input
display for the first operand will be displayed.
WRITE
• Writing Hexadecimal, BCD Constant
10. Input the first operand.
B
A
CONT
1
0
#
Press the WRITE Key to write the instruction to Program Memory. The input
display for the second operand will appear.
WRITE
• Writing a Word Address
11. Input the second operand.
B
LR
1
Press the WRITE Key to write the instruction to Program Memory. The next
program address will be displayed.
WRITE
00201 TIM DATA
00202READ
NOP(000)
00202
B
1
MOV(021)
00202 MOV DATA A
00202 MOV DATA A
A
0
00202 MOV DATA B
00202 MOV DATA B
A
0
00203READ
NOP(000)
Section 4-3
#0000
000
#0100
000
LR 10