SAFETY / LISTING LABEL - DRI2032TEN
C
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL
CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 & CAN/CGA-2.17-M91 (R2009).
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA
54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY
OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER'S
MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT,
FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22.1-LATEST EDITION (CANADA).
MINIMUM FIREPLACE SIZES REQUIRED
Front Opening ........................................................................32" (813mm)
Height ......................................................................................19-1/2" (495mm)
Rear Width ............................................................................. 22" (559mm)
Depth ...................................................................................... 16" (406mm)
MINIMUM CLEARANCES TO COMBUSTIBLES
A = Mantel ...............................................................................32" (813mm)
B = Side Wall ..........................................................................4" (102mm)
*C = Mantel Depth ..................................................................10" (254mm)
HEARTH PROTECTION
D = Vertical Distance from base of appliance ..................
to Hearth Extension ......................................................... (0mm) (102mm)
E = Minimum Horizontal Distance ........................................ 10"
from Front of Appliance ................................................... (254mm) (0mm)
*See owner's manual for additional mantel clearances and options.
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
MANIFOLD PRESSURE (IN. WC)
MIN. INLET PRESSURE (IN. WC)
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M. ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
CHIMNEY - USE 3" (76 MM) GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (305 M).
CAUTION:
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT
OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE
AGENCY OR GAS SUPPLIER.
WARNING: FAILURE TO INSTALL THIS APPLIANCE PER THE MANUFACTURER'S INSTRUCTIONS OR FAILURE TO
USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR
PERSONAL INJURY.
2016
2020
Part No. 900791-01 Rev. 1, 11/2016
MODEL
MANUFACTURED BY:
US
INNOVATIVE HEARTH PRODUCTS
Report No. 16-204
AUBURN, WA., USA 98001
....................
DRI2032TEN
RATINGS
NATURAL GAS
28,000 / 16,000
#38 (.101")
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
DATE OF MANUFACTURE / DATE DE FABRICATION
2017
2018
2019
JAN
FEB
2021
2022
2023
DO NOT REMOVE OR COVER THIS LABEL
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SERIAL
DRI2032TEN
DRI2032TEN
NO.
1502 14TH ST NW
MINIMUM CLEARANCES
C
Mantel
A
0"
4"
0"
E
DRI2032TEN
LP GAS
25,000 / 14,000
3.5
10.0
5.0
10.5
#53 (.0595")
AUG
MAR
APR
MAY
JUN
JUL
Mantel
B
D
Non-Combustible
For use only with barrier
Part No. J4785. Follow
installation instructions.
SEP
OCT
NOV
DEC
IGN _________