Superior Fireplaces DRL4543TEP Assembly, Installation And Operation Instructions

Direct-vent linear gas fireplace

Advertisement

Quick Links

P/N 126718-01 Rev. N 04/2020
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 126718-02.
P126718-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
PFS
®
C
US
Report No. F11 -026
NOTE: DIAGRAMS AND ILLUSTRATIONS THROUGHOUT THE MANUAL ARE NOT TO SCALE.
Installation and Operation Instructions
DRL4500 Series Direct-Vent Linear Gas Fireplace
Models
DRL4543TEN
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRL4543TEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces DRL4543TEP

  • Page 1 Models Ce manuel est disponible en francais, simplement ® DRL4543TEN en faire la demande. Numéro de la pièce 126718-02. DRL4543TEP Report No. F11 -026 P126718-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future Consommateur : Conservez cette notice pour reference.
  • Page 2: Safety And Your Fireplace

    SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and must be installed for the protection of children and other at-risk individuals.
  • Page 3 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTREMELY HOT! EXTRÊMEMENT CHAUDES ! MUY CALIENTES! ...
  • Page 4: Table Of Contents

    Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
  • Page 5 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de importante tion seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked, si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6 SAFETY Continued This fireplace must be installed by a qualified (certified or licensed) Installation and repair should be done by a qualified service person. It brings in fresh air for combustion through the outer service person. The appliance should be inspected pipe and combustion gases are exhausted through the inner pipe.
  • Page 7: Local Codes

    SAFETY Continued the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical 6. Have venting system inspected annually by a qualified service Code, CSA C22.1. person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, Page 36. 9. Do not use fireplace if any part has been exposed to or under water.
  • Page 8: Product Features

    PRODUCT FEATURES These are a few facts that can help you understand and enjoy your • This fireplace may be installed in any room of your house provided direct-vent fireplace: all local codes and these installation instructions are followed. • The venting system may be routed to the outside of your home in •...
  • Page 9: Pre-Installation

    PRE-INSTALLATION LOCATION AND SPACE REQUIREMENTS CLEARANCES Determine the safest and most efficient location for your direct-vent Minimum clearances to combustibles for the fireplace are as follows: fireplace. Make sure that rafters and wall studs are not in the way *Back and sides 1"...
  • Page 10 PRE-INSTALLATION Continued " MOUNTED INSIDE OF (445 mm) FOR ONE SIDED NAILING FLANGE APPLICATION, STUDS (FLAT) ARE NOT MOUNTED Concrete TO THE REAR Board OF NAILING FLANGES 38" (965 mm) " (1353 mm) Figure 4 - Installing Concrete Board Wall Figure 2 - Framing Clearances for One Sided Application "...
  • Page 11 PRE-INSTALLATION Continued " " " (54 mm) (1114 mm) (206 mm) " (419 mm) " " (298 mm) " (445 mm) (210 mm) " (16 mm) " (210 mm) " (89 mm) " (759 mm) " " (759 mm) (416 mm) "...
  • Page 12: Location Of Termination Cap

    LOCATION OF TERMINATION CAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) I = clearance to service regulator vent outlet [*72" (182.9 cm) A = clearance above grade, veranda, porch, deck, or balcony [*12"...
  • Page 13: Venting Installation

    VENTING INSTALLATION INSTALLATION PRECAUTIONS NOTICE: Read these instructions completely before • Wear gloves and safety glasses for protection attempting installation. • Use extreme caution when using ladders or when on roof tops These models are tested and approved for use with an IHP (direct- •...
  • Page 14 VENTING INSTALLATION Continued INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination Installing the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 15 VENTING INSTALLATION Continued NOTE: The firestop/spacer may also be installed over the 1. Continue installation of horizontal/inclined sections— Continue with the installation of the straight vent sections opening at the interior side of the framing. in horizontal/inclined run. Install support straps every 1.
  • Page 16 VENTING INSTALLATION Continued *Use silicone caulking to Maximum wall thickness seal the top and sides of 9-1/4” (235 mm)** the termination, up to the Interior Surface of underlayment, stucco, or Finished Wall Exterior Surface of Siding masonry wall surface. Maximum Extent of Exterior Surface of Vent Run Sections Framing...
  • Page 17 VENTING INSTALLATION Continued Connecting the vent pipe 1. Push the vent component against the collar until it fully engages, then twist the component clockwise, running the Direct-vent system components are unitized concentric pipe dimples down and along the incline channels until they seat components featuring positive twist lock connections (Figure 11 at the end of the channels.
  • Page 18 VENTING INSTALLATION Continued GROUND FLOOR INSTALLATION Recommended Applications: • Through the wall using round or square termination 1' Pipe Min. On 90° Elbow Horizontal Run V + 90· Elbow Wall Firestop *Firestop/Spacer (SV4.5HF) shown on the exterior side of the wall. It SV4.5 HTSS may also be installed on the Termination...
  • Page 19 VENTING INSTALLATION Continued Install the Vertical Termination Vent System Vertical (Offset) Installation These instructions should be used as a guideline and do not super- 1. Analyze the vent route and determine the number of vent sede local codes in any way. Install venting according to local codes, sections and elbows required—See Effective Vent Length these instructions, the current National Fuel Gas Code (ANSI-Z223.1) on Table 2, Page 14 for more information.
  • Page 20 VENTING INSTALLATION Continued 1. Install the roof flashing—Extend the vent sections through the roof structure. Install the roof flashing over the vent sec- tion and position such that the vent column rises vertically (use carpenters level). Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only and trim where necessary.
  • Page 21 VENTING INSTALLATION Continued NOTE: SV4.5VF firestop/spacer must be used anytime vent pipe pass- Venting with Two 90° Elbows es through a combustible floor or ceiling. SV4.5HF firestop/spacer must be used anytime vent pipe passes through a combustible wall. Vertical (V Horizontal (H) feet (meters)
  • Page 22 VENTING INSTALLATION Continued PARTS LIST FOR VENTING KITS AND COMPONENTS IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ® Cat. No. Model Description Cat.
  • Page 23 VENTING INSTALLATION Continued IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ® Cat. No. Model Description Cat. No. Model Description 96K93 SV4.5SU Support Strap...
  • Page 24 VENTING INSTALLATION Continued VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX KITS AND COMPONENTS Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5) direct-vent components can ® be used. All restrictions, clearances and allowances pertaining to rigid vent also apply to flexible vent. Do NOT modify Secure Flex kits . Also, do NOT join separate sections of flex vent together.
  • Page 25: Fireplace Installation

    VENTING INSTALLATION Continued NOTE: See the appropriate sections and figures shown Install three (3) screws 120° apart through the flexible vent throughout the venting section for installation requirements. and into the adaptor collar just below the gear clamp to provide additional security to the connection.
  • Page 26 FIREPLACE INSTALLATION Continued Equipment Shutoff Valve External Regulator with with 1/8" NPT Tap* Vent Pointing Down Propane/LP Supply Tank Natural - From Gas Meter (5.5" W.C. to Approved 10.5" W.C. Pressure) Flexible Gas Propane/LP From Line External Regulator (11" W.C. to 14" W.C. 3"...
  • Page 27 FIREPLACE INSTALLATION Continued CHECKING GAS CONNECTIONS Equipment Shutoff Valve WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing Propane/LP Supply Tank or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak.
  • Page 28 FIREPLACE INSTALLATION Continued For one sided regular application, finish installing rear panel by securing with 19 self tapping screws included with fireplace. Figure 34 - Latch Opener Replacing Glass Door 1. Position door frame in front of firebox opening tilting top of door about 45°...
  • Page 29 FIREPLACE INSTALLATION Continued NOTE: All models must have a barrier installed prior to operation. Place dime sized embers Hold the barrier in front of the glass door and slide it up into the only on the channel underneath the upper front face (see Figure 37). burner.
  • Page 30 FIREPLACE INSTALLATION Continued Retaining Bracket Figure 41 - Installing Access Door Retaining Brackets for See- Thru Applications Figure 39 - Removing Mount Bracket for See-Thru Applications Removing False Door 1. In the rear of the fireplace, remove false door just as you would remove the front glass door.
  • Page 31 FIREPLACE INSTALLATION Continued UPGRADING DRL4543 TO INDOOR/OUTDOOR SEE-THRU Fireplace APPLICATION Face WARNING: LDSTIB must be installed before in- stalling LDSTOB. Installing Exterior Door 1. Center and level exterior door on rear face of the see-thru fireplace. Exact dimensions for the location of the door are shown in Figure 44. 2.
  • Page 32: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD It is required that the safety instruction labels fur-...
  • Page 33: Operation

    OPERATION FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS NOTICE: During initial operation of new fireplace, WARNING: If you do not follow these instructions burning will give off a paper-burning smell. Orange exactly, a fire or explosion may result causing property flame will also be present.
  • Page 34: Homeowner - Attaching Safety In Operation Warnings

    HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and Votre foyer a été...
  • Page 35: Inspecting Burners

    INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located Pilot on right hand side of burner. Burner The flame must envelope 1/4"...
  • Page 36: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before CAUTION: Do not vacuum if pieces are hot. cleaning. Use only glass door replacement intended for this fireplace (see Replacement Parts, Page 47 for detail on ordering). No substitutions CAUTION: You must keep control areas, burners may be made.
  • Page 37: Gas Control Module System

    GAS CONTROL MODULE SYSTEM The module has 2 special features built into the system. BATTERY BACK-UP Continuous Pilot Feature This fireplace is equipped with a battery back-up. If the power was to go out on the fireplace, the battery back-up allows the fireplace to This allows the change from a spark to pilot system to a standing remain operational.
  • Page 38 REMOTE CONTROL OPERATION Continued • Temperatures may be displayed in degrees F (factory default) or degrees C. Press the up and down buttons simultaneously to change between degrees F. and C. MODE Zone Cont. ROOM Pilot MODES OF OPERATION ROOM TEMP Zone Operation modes: °...
  • Page 39: Specifications

    • Maximum Inlet Supply Pressure: 10.5" w.c. the MODE/SET and DOWN Buttons simultaneously for 5 seconds. • Orifice: #33 • LCD Displays: DRL4543TEP • When activated, the LOCK icon will appear in the MODE • Rating: 33,000/24,000 Btu/hr Zone. • Gas Type: Propane/LP Gas Only •...
  • Page 40: Wiring Diagram

    WIRING DIAGRAM Green Orange White (J7868) HI/LO DC Pilot Motor Drive (J7854) Valve Power Main (J7864) Module White Yellow Blue BATTERY PACK Orange Brown Black SIZE SIZE SIZE SIZE (J7865) "AA" "AA" "AA" "AA" Black To Ground Brown To Rocker Switch Brown (+) Red Blk/White (+)
  • Page 41: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. NOTE: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 42 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Page 43: Parts

    PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on Page 47 of this manual. 126718-01N SuperiorFireplaces.us.com...
  • Page 44 Page 47 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. DRL4543TEN DRL4543TEP CATALOG DESCRIPTION (F1262) (F1263) QTY.
  • Page 45 PARTS MODELS: DRL4543TEN AND DRL4543TEP 126718-01N SuperiorFireplaces.us.com...
  • Page 46 PARTS MODELS: DRL4543TEN AND DRL4543TEP WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. DRL4543TEN DRL4543TEP CATALOG NO.
  • Page 47: Replacement Parts

    ACCESSORIES TECHNICAL SERVICE Purchase this accessory thru your IHP distributor or dealer. You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns a. When contacting your dealer please have your model CAT NO.
  • Page 48 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ SuperiorFireplaces.us.com 126718-01N...
  • Page 49: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 50 SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Drl4543tenDrl4500 seriesDrl4543Drl4543-stF1262F1263