Siemens XQG120 User Manual And Installation Instructions page 59

Table of Contents

Advertisement

Fault
The laundry is too
damp.
Loud noises during
the spin cycle.
Banging noises, rat-
tling in the drain
pump.
Slurping, rhythmical
suction noise.
Fan noise during the
washing phase.
Longer, whirring noise
before the start of the
wash cycle or fabric
softening.
Brief whirring noise
after switching on the
appliance.
Cause and troubleshooting
Make sure that the water tap also remains open
during the drying phase.
The ambient temperature is greater than 30 °C.
Ensure that the appliance is only operated in a well
ventilated location.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
The water pressure is low.
No remedial action possible.
Laundry is not spun sufficiently.
Always select the highest possible spin speed for
the washing programme in question.
Thick and multi-layered fabrics require a longer drying
time.
Set a timed programme for the subsequent drying.
→ "Programmes", Page 29
Appliance is not correctly aligned.
→ "Aligning the appliance", Page 16
The appliance feet are not fixed.
Secure the appliance feet.
→ "Aligning the appliance", Page 16
Transit bolts have not been removed.
→ "Removing the transit bolts", Page 14.
Foreign bodies have got into the drain pump.
→ "Cleaning the drain pump", Page 47
The drain pump is active, the detergent solution is
pumped out.
Not a fault – normal operating noise.
Process fan is active.
Not a fault – normal operating noise.
Intelligent dosing system dispenses detergent or care
products.
Not a fault – normal operating noise.
Intelligent dosing system carries out a function test.
Not a fault – normal operating noise.
Troubleshooting en
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws74d8a10w

Table of Contents