Connection Procedure - Omron F3SJ-A P 01TS Series User Manual

Safety light curtain
Hide thumbs Also See for F3SJ-A P 01TS Series:
Table of Contents

Advertisement

Connection Procedure

 When Using the F39-JJRL Series Connection Cable for Close Contact
(sold separately)
1.
Remove the connection cable of the secondary-side F3SJ. (driver comes with F39-JJRL)
2.
Remove the cap from the secondary-side F3SJ.
3.
Use the F39-JJRL series connection cable for close contact to connect them.
Power cable
Enlarged view of emitter
power supply connector side
Emitter power supply
connector side
- Attaching/detaching of a cap or a series-connection cable may cause misalignment of rubber grommet in a connector
assembly. Press the grommet to the bottom of the connector and attach the connector F3SJ again.
p.60
- Use the F39-JJRL series connection cable for close contact when the connection distances between F3SJ are short
for a L-shaped configuration, and use the F39-JJR3W (and F39-JDB) series connection cable for extension when
the connection distances are long.
Ex.: L-shaped configuration
Emitter
power supply
1. 1.
connector side
Receiver
power supply
connector side
3. 3.
F39-JJR L
2. 2.
Cap
Series connection cable for close contact
F39-JJR L
1. 1.
Power cable
3. 3.
F39-JJR L
2.
2.
Cap
Enlarged view of receiver
power supply connector side
Receiver power supply
connector side
Wiring/Installation
F3SJ-A
User's Manual
E
57

Advertisement

Table of Contents
loading