 Timing Chart
ON
Muting sensor A1
OFF
ON
Muting sensor B1
OFF
ON
Muting sensor A2
OFF
ON
Muting sensor B2
OFF
Enabled
Muting state
Disabled
Blinking
Muting lamp
(External indicator)
OFF
F3SJ Unblocked
Unblocked
/Blocked
Blocked
ON
Safety output
OFF
*1 The value is applied to a single sensor. Values for connected sensors are:
# of connections
Single
0.15
2 connected
0.26
3 connected
0.29
•T1min: Muting input time limit (minimum value)
This is set to 0.03 sec., the minimum value for the input time difference between muting input 1 and 2.
A muting error occurs when the input time difference between muting input 1 and 2 is less than this
value.
•T1max: Muting input time limit (maximum value)
This is set to 3 sec., the maximum value for the input time difference between muting input 1 and 2.
•T2: Muting time limit
This is set to 60 sec., the muting function continuation time. When this muting state exceeds this time,
muting is released.
•T3: Muting input time with allowable waveform cracks
This is the maximum value for the waveform cracks allowed for muting input 1 and 2 when muting is
in effect. It is set to 0.1 sec.
T3(0.1s ) max.
T1min to T1max
0.15s max. *1
*1 Value (s)
System Configuration and Functions
T3(0.1s ) max.
T3(0.1s ) max.
T3(0.1s ) max.
T2 max.
E
F3SJ-A
37
User's Manual