Omron F3SJ-A P 01TS Series User Manual page 129

Safety light curtain
Hide thumbs Also See for F3SJ-A P 01TS Series:
Table of Contents

Advertisement

 Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts are movable when nothing is in the detection zone.
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SJ is turned OFF while nothing is in the detection
zone.
 Items to Inspect Every 6 Months or When Machine Settings Are Changed
In addition to inspection item at operation start, following items must also be verified.
The outputs of the F3SJ and the machine are properly wired.
The total number of times that the control relays/contactors have switched is significantly lower than
their design lives.
There is no disturbance light.
When F3SJ is connected again, a secondary sensor farthest from its power supply has either of the
followings:
- Cap
- Key cap for muting
- Muting lamp (set of lamp and cable)
Power supply's 0V must be grounded.
Wiring must not be bent, cracked, nor damaged.
Checklists