Error code
Error Description
38
Lockout of other
C
sensor than the
primary receiver
(error mode
B
indicator will not
turn on)
A
3A
Excessive number
of beams
C
B
3B
Excessive number
of connected
A
sensors
3C
Model error
(between series
connection)
3D
Model error
(between emitter/
receiver)
3E
Sensor count
error (no emitter)
3F
Sensor count
error (no receiver)
4E
Cap position error Failure of F3SJ's internal circuit.
C
4F
Cap error
B
A
50, 51, 52, 53 External device
C
monitoring error
B
A
Cause
A sensor other than the primary
receiver is in lockout when series-
connected.
Total number of beams of F3SJs
under series connection exceeds
240.
Four or more sensors are
connected.
Models of the primary sensor and
secondary sensor are unavailable
for connection. (Primary: PNP
Output, Secondary: NPN Output,
etc.)
Models are different between an
emitter and a receiver (lengths,
output types, or beam gaps are
different)
Number of emitters under series
connection is less than that of
receivers (emitters: 2, receivers:
3, etc.)
Number of receivers under series
connection is less than that of
receivers (emitters: 3, receivers:
2, etc.)
Cap is not attached.
A contact failure due to the loose
cap, the intrusion of liquid (oil etc.)
into the cap, or the attachment of
a foreign material has occurred.
Relay is welded.
The relay and external device
monitoring input line are not
properly wired.
The relay response time exceeds
the allowable delay time.
If short-circuit is made to an
auxiliary output instead of a relay,
the auxiliary output line is broken
or short-circuited.
Emitter(s) and receiver(s) are
reversely connected when
connected to connector type
controller.
(Connectors of F3SP-B1P's
emitter/receiver are reversely
attached, etc.)
Solution
Solve the problem of an emitter or
F3SJ in a series connection.
Rearrange series connection so
that total number of beams of
series connection should not
exceed 240.
Number of F3SJs under series
connection must be 3 or less.
Connect them properly.
p.55
Replace the F3SJ.
Attach the cap properly.
After cleaning the inside of the
cap (if any foreign material is
attached), tighten the cap more
closely. Replace the cap if any
liquid such as oil has intruded.
Replace the relay.
Check the wiring for the relay.
Replace the relay with one that
has an appropriate response time.
Make sure there is no failure in
the external device monitoring
input and auxiliary output lines.
Check connectors' positions.