Omron F3SJ-A P 01TS Series User Manual page 59

Safety light curtain
Hide thumbs Also See for F3SJ-A P 01TS Series:
Table of Contents

Advertisement

 Override End Conditions
When either of the following conditions is satisfied, the function is released.
•When 60 seconds has elapsed under the override state
•All muting sensors are turned OFF
•When the reset input turns from OFF to ON
Override state can be released if a sensor transitions to lockout as well.
ON
Muting input 1
OFF
ON
Muting input 2
OFF
ON
Reset input
OFF
Enabled
Override state
Disabled
blinking
Muting lamp
(External indicator)
OFF
Unblocked
F3SJ Unblocked
Blocked
/Blocked
ON
Safety output
OFF
 Operation of the F3SJ's Internal Indicators When Override Function Is Performed
•Muting input 1 indicator turns ON when an input is applied to muting input 1.
•Muting input 2 indicator turns ON when an input is applied to muting input 2.
•Muting input 1 and 2 indicators blink while muting overriding
•Muting error indicator turns ON when a muting error occurs.
0.04 to 3s
0.04 to 3s
Within 3s
3s or longer
*1 There are 3 override end conditions. For details, see override end conditions.
- T2: Override Time Limit
Continuance time of overriding. If override state exceeds this time, the
function is canceled.
System Configuration and Functions
*1
T2 max.
0.25s max.
E
F3SJ-A
41