System Configuration and Functions
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ and muting sensors so that a workpiece passes through all
muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
 Wiring Diagrams
Using a photoelectric switch as a muting sensor
A1
Two-wire type muting sensor cannot be used.
*
F3SJ-A
36
User's Manual
Workpiece
Moving direction
B1
B2
A1, B1, A2, B2 :
Regressive reflection
photoelectric switch
- PNP Output
- ON when Interrupted
A2
F3SJ
Workpiece
Workpiece
Moving direction
Using an N.O contact type switch as a muting sensor
A1
A2
B1
B2
A1, A2, B1, B2:
N.O contact type switch
+24V DC
Power
supply
0V