Extron electronics DTP T USW 333 User Manual page 18

Three input switcher with integrated dtp transmitter
Hide thumbs Also See for DTP T USW 333:
Table of Contents

Advertisement

Power supply wiring
NOTES:
The power supply included with the switching transmitter can normally power both
units.
If you have removed the ground jumpers (see
page 32) because of ground potential differences, one unit of the pair cannot
remotely power the other unit. Each unit requires a local power supply.
Figure 6 shows how to wire the connector. Use the supplied tie-wrap to strap the power
cord to the extended tail of the connector.
Smooth
Ridges
A
A
SECTION A–A
Power Supply
Output Cord
Figure 6.
Power Connector Wiring
CAUTION:
ATTENTION :
The wires must be kept separate while the power supply is plugged in. Remove
power before wiring.
Les deux cordons d'alimentation doivent être tenus à l'écart l'un de l'autre quand
l'alimentation est branchée.
The length of exposed wires is important. The ideal length is 3/16 inch (5 mm).
Any longer and the exposed wires may touch, causing a short circuit between
them.
Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
La longueur des câbles exposés est importante. La longueur idéale est de
5 mm (3/16 inches).
S'ils sont un peu plus longs, les câbles exposés pourraient se toucher et
provoquer un court circuit.
S'ils sont un peu plus courts, ils pourraient sortir, même s'ils sont attachés par
les vis captives.
Do not tin the power supply leads before installing them in the connector. Tinned
wires are not as secure in the connector and could be pulled out.
Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles
étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés.
Disconnecting the Ground
Tie Wrap
5
3
Captive Screw
Connector
DTP T USW 333 • Installation and Operation