Technical Data - Graco ProMix II Service And Parts

Hide thumbs Also See for ProMix II:
Table of Contents

Advertisement

Technical Data

Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . see page 4
Maximum working air pressure . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75–100 psi (0.5–0.7 MPa, 5.2–7 bar)
Air filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 micron (minimum) filtration required
Mixing ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1:1–30:1*
On-ratio accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to + 1%, user selectable
Fluids handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . one or two component:
Viscosity range of fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . 20–5000 cps*
Fluid filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mesh minimum
Fluid flow rate range*
G3000 Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G3000HR Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Coriolis Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Power Supply Requirements . . . . . . . . . . . . . . . 85–250 Vac, 50/60 Hz, 2 amps maximum draw
Operating temperature range . . . . . . . . . . . . . . . . . . . . . . 41–122° F (5–50° C)
Environmental Conditions Rating . . . . . . . . . . . . . . . . . . . Indoor use, Pollution degree (2). Installation category II.
Noise Level
Sound pressure level . . . . . . . . . . . . . . . . . . . . . . . . .
Sound power level . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303, 304 SST, 17–4 SST, Tungsten carbide (with nickel
Weight
Base System Total (no meters color change valves
or gun flush box). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66.6 lbs (30.2 kg)
EasyKey™ Display. . . . . . . . . . . . . . . . . . . . . . . . 22.2 lbs (10.1 kg)
Smart Fluid Panel (no meters) . . . . . . . . . . . . . . . 41.3 lbs (18.7 kg)
Operator Station. . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 lbs (1.5 kg)
Optional Components
G3000/G3000HR Flow Meter . . . . . . . . . . . . . . . 6 lbs. (2.7 kg) each
Coriolis Flow Meter . . . . . . . . . . . . . . . . . . . . . . . 33 lbs. (15 kg) each
Low Pressure Color Change Stack (6 color) . . . . 3.0 lbs (1.4 kg)
High Pressure Color Change Stack (6 color). . . . 11.0 lbs (5.0 kg)
Gun Flush Box . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 lbs. (9.6 kg)
*
Dependent on programmed K-factor and application. The ProMix™ II maximum allowable flow meter pulse fre-
quency is 425 Hz (pulses/sec.). For more detailed information on viscosities, flow rates, or mixing ratios, consult
your Graco distributor.
See individual component manuals for additional technical data.
310653B
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
75–3000 cc/min. (0.02–0.79 gal./min.)
38–1500 cc/min. (0.01–0.40 gal./min.)
20–3800 cc/min. (0.005–1.00 gal./min.)
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
below 70 dBA
below 85 dBA
binder), perfluoroelastomer; PTFE; CV75
Technical Data ◆
39

Advertisement

Table of Contents
loading