Promix™ Ii Models - Graco ProMix II Service And Parts

Hide thumbs Also See for ProMix II:
Table of Contents

Advertisement

ProMix™ II Models ◆
ProMix™ II Models
WARNING
Do not install equipment approved only for non-haz-
ardous location in a hazardous area. Substitution of
components may impair intrinsic safety. See page 6.
PM
ProMix™ II
Unit
PM
0
1
2
3
Hazardous Location Approval
Only models with a G3000 (1) or G3000HR (2) for both A and
B meters are approved for installation in a Hazardous Loca-
tion - Class I, Div I, Group D, T3.
Non-hazardous Location Approval
CAN/CSA
22.2 No.1010.1
Maximum Working Pressure
Maximum working pressure rating is dependent on the A and B meter and color change option selected. The pres-
sure rating is based on the rating of the lowest rated fluid manifold component. Refer to the component pressure
ratings below. Example: Model PM1140 has a maximum working pressure of 3000 psi (21 MPa, 207 bar).
Check the ID plate on your EasyKey™ Display or fluid panel for its maximum working pressure. See F
page 5.
ProMix™ II Fluid Manifold Components Maximum Working Pressure
Color Change Option 1, 2, or 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (2.1 MPa, 21 bar)
Color Change Option 4, 5, or 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 psi (21 MPa, 207 bar)
Coriolis A and B Meters Option 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2300 psi (16 MPa, 159 bar)
No Meters or G3000 or G3000HR A and B Meters Option 0, 1, or 2 . . . . . . . . . . . . . . . 4000 psi (28 MPa, 276 bar)
Flow Meter Fluid Flow Rate Range
G3000 Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75-3000 cc/min. (0.02-0.79 gal./min.)
G3000HR Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-1500 cc/min. (0.01-0.40 gal./min.)
4
Enter
A Meter
B Meter
None
0
None
G3000
1
G3000
G3000HR
2
G3000HR
Coriolis
3
Coriolis
WARNING
Changing the fluid manifold configuration may change
its pressure rating. Do not exceed the pressure rating
of the lowest rated component. See page 6.
Model
number
Color Change
0
None, Single Color
1
2 Color, Low Pressure
2
4 Color, Low Pressure
3
6 Color, Low Pressure
4
2 Color, High Pressure
5
4 Color, High Pressure
6
6 Color, High Pressure
Conforms to FM std
3600 & 3610 for use in
Class I Div 1 Group D T3
Hazardous locations
here
Gun Flush
0
1
EEx ib IIA T3
CAN/CSA
ISSeP 04 ATEX 008
22.2 No.157 &
SYST
No. 1010.1-92
Box
No
Yes
. 1,
IG
310653B