Graco ProMix II Service And Parts page 23

Hide thumbs Also See for ProMix II:
Table of Contents

Advertisement

Installing
9.
Screw meter (1) securely onto the dispense valve
connector (H), using a wrench.
CAUTION
To avoid leakage, secure the meter (1) to the dis-
pense valve connector (H) before connecting it to the
plate (108).
10.
Secure meter (1) to plate (108) with screws (107).
11.
Connect meter cable (110). See F
12.
Connect fluid line (P).
13.
Calibrate meter as instructed in ProMix™ II
Operation manual.
J3*
Power (red)
1
Common (black)
2
Signal (white)
3
Shield
4
Power (red)
5
Common (black)
6
Signal (white)
7
8
Shield
*Connector on Smart Fluid Panel circuit board
F
. 21: G3000 or G3000HR Cable Schematic
IG
Servicing Fluid Manifold
WARNING
Follow
Pressure Relief
servicing equipment. Read warnings, page 6.
Removing
1.
Follow
Servicing Flow Meters
1-7, page 22.
2.
Disconnect air and fluid lines from the manifold
(17).
3.
Holding onto the fluid manifold (17), remove the 4
screws (18). To ease screw removal, use a long
T-handle Allen wrench.
310653B
. 21.
IG
Cable
Flow Meter A
Flow Meter B
Cable
Procedure, page 8, before
procedure, steps
4.
Remove fluid manifold (17).
5.
Service fluid manifold as instructed in the Fluid Mix
Manifold manual.
Installing
6.
Secure fluid manifold (17) to mounting plate (13)
with 4 screws (18).
7.
Install meters (1). See steps 9-11, at left.
8.
Connect air and fluid lines.
9.
Calibrate meter as instructed in ProMix™ II
Operation manual.
F
. 22
IG
Service ◆ Smart Fluid Panel
18
13
TI4859a
Item 17
23