Service ◆ Smart Fluid Panel
Reassemble Smart Fluid Panel
1.
Remove screws and slide the panel (14) back into
place.
2.
Secure the cover (15) and panel (14) with the 4
screws (16). F
. 18.
IG
F
. 18
IG
Servicing Flow Meters
WARNING
Read warnings, page 6.
Coriolis Meter: To remove and service see Coriolis
meter manuals.
G3000 or G3000H Meter: To remove, follow proce-
dure below. To service, see meter manual.
G3000 or G3000HR Meter
Removing
1.
Follow
Pressure Relief
sure you complete step 11.
2.
Close main air shutoff valve on air supply line and
on ProMix™ II.
22
14
15
16
Procedure, page 8. Make
3.
Shut off ProMix™ II power (0 position).
4.
Unscrew cable connector (110) from meter (1). F
20.
5.
Unscrew M6 screws (107) from bottom of meter
mounting plate (108) with socket wrench. F
6.
Unscrew fluid line from meter inlet (P).
The meter shield (R) is unattached and may fall off
when you remove the meter (1). F
7.
Unscrew meter (1) from dispense valve connector
(H). F
. 20.
IG
8.
Service meter as instructed in the meter manual.
107
108
F
. 19
IG
110
R
1
F
. 20
IG
. 19.
IG
. 20.
IG
P
H
310653B
.
IG