Characteristics; Specifications - Delta ASRTU-EC16AP Operation Manual

Ethercat remote communication module
Table of Contents

Advertisement

ASRTU-EC16AP EtherCAT Remote Communication Module Operation Manual
1. Thank you for choosing Delta ASRTU-EC16AP. To ensure correct installation and operation of the
unit, please read this manual carefully before use.
2. This manual only provides introductory information on ASRTU-EC16AP. For more detailed
information on EtherCAT protocol, please refer to relevant references or literatures.
3. ASRTU-EC16AP is defined as an EtherCAT remote slave and AS series DI/DO modules and AI/AO
modules can be connected on its right side. (Note: The communication module and positioning
_2
module are not allowed to connect on the right side of ASRTU-EC16AP.)
4. Refer to AS Series Module Manual for more details on how to use AS series extension modules.
5. ASRTU-EC16AP series includes the two models: ASRTU-EC16AP1TA and ASRTU-EC16AP1PA.
ASRTU-EC16AP1TA's local output points are NPN transistor outputs and ASRTU-EC16AP1PA's
local output points are PNP transistor outputs.

2.1 Characteristics

Compliant with the EtherCAT protocol, supports PDO, SDO and other services in the CoE protocol
as well as Hot Connection function.
Supports Distributed Clock SYNC, SyncManagers and Free Run.
8 digital input points and 8 digital output points are built in ASRTU-EC16AP
2 channels for high-speed counting with counting modes of single pulse, "pulse+direction" and
"phase A+phase B" and maximum input frequency of 200kHz
2 channels for high-speed pulse output with pulse output modes of "pulse+direction", "Phase A +
phase B" and CW/CCW with a maximum of 200 kHz output frequency.
(Note: the maximum output frequency is 100 kHz for the "phase A+phase B" output mode)
Supports AS series extension modules including digital modules, analog modules, load cell
modules and temperature measurement modules.
Maximum 32 modules in total including digital modules and special modules can be connected to
the right side of ASRTU-EC16AP, among which the maximum number of special modules like
analog modules, temperature measurement modules and load cell modules is 16.
Maximum 1024 points in total for digital input and output, which include the input and output points
built in ASRTU-EC16AP
Ability to realize the high-speed remote I/O control with the minimum cycle (DC time) of 500 µs.
The node address of ASRTU-EC16AP can be set by the rotary address switches.

2.2 Specifications

Electrical specification
Power voltage
Consumption power
Insulation impedance
Rush current
Fuse
Power protection
Surge voltage withstand level
2-2
Item
24 VDC (-15% ~ 20%)
1.8 W
> 5MΩ (500 VAC between all inputs/outputs and the ground)
240 A (@24VDC, I2t = 4.5 A2S)
2.5 A / 250 VAC
The DC power input is equipped with reverse polarity
protection.
3,000 VAC (Primary-secondary), 3,000 VAC (Primary-FE),
500 VAC (Secondary-FE)
Specification