Apply The Label; Connect To The Computer; Connect To Mirus - Juniper HarvestMaster GrainGage H2 NIR Upgrade Installation Manual

Table of Contents

Advertisement

H2 NIR Upgrade Installation Guide

2.5 Apply the Label

2.6 Connect to the Computer

1. Position a 30712 Serial to USB cable from the junction cable to the cab. Follow the same path as the
CAN cable or use a cleaner path if available. If needed, you can use the 31518 SCiO 15 ft extension
cable here.
2. Plug the USB end of the serial to USB cable into the USB Port of the tablet. Secure the USB end so
that it can't vibrate out.

2.7 Connect to Mirus

1. Download and install Mirus 4.5.0 or above.
Note: When asked to launch Mirus, do NOT launch.
2. Enable the H3 Plugin in the Plugin Manager.
3. Install the SCiO Service for the sensor.
Note: Each sensor has its own activation link. If you have not yet received your link,
a. Go to harvestmaster.com/support. Tap My Product.
b. Tap SCiO License Renewal.
4. Open Mirus and connect to the H3 GrainGage plugin.
If Mirus does not successfully connect to the H3 GrainGage, complete the following steps in order.
a. Press the red button on the system controller to power off the GrainGage.
b. Close Mirus.
c. Unplug the CAN to USB cable from the computer.
d. Unplug the serial to USB cable from the computer.
Install NIR Upgrade for Classic
1. Install the new H3 GrainGage label.
30