Item number
Item
712
VIDEO PROCESS
ON CAP LOCK
2 FIELD
713
VIDEO SETUP
(DVW-A500/1
REFERENCE
and 500/1 only)
LEVEL
Sub item
MASTER
0
LEVEL
1
INPUT LEVEL
INPUT VBLK
2
CONT
3
BATACAM PB
LEVEL
4
OUTPUT LEVEL
714
VIDEO ADJUST
RANGE
Settable range
Function
[0]
[off]
When 2 FLD is selected by the ALT/[F5] (CAP LOCK) button
on
in the HOME menu, or by the item 106 "CAPSTAN LOCK",
1
this item specifies whether the picture shift in 2-field mode
playback applies or not.
0: Picture shift does not apply.
1: Picture shift applies.
Note
When recording composite signals, the composite input
signal is first converted to a component digital signal by
decoder (optional BKDW-505 for DVW-A500/1 and 500/1, or
BKDW-506 for DVW-A500P/1 and 500P/1) before it is
recorded.
To eliminate the adverse effect of the residual chroma
subcarrier component in the Y signal (the result of Y/C
separation), 4-field color framing is normally conducted for
playback (for NISC) or 8-field (for PAL). This VTR, however,
is able to produce high picture quality through automatic
shifting of the playback picture in the H direction even with 2-
field (for NISC) or 2- or 4-field (for PAL) playback.
The sub items in this setting specify the amount to be
subtracted from the setup level in the case of the recording
signal and Betacam playback signal, or the amount to be
added to the setup level in the case of a component output
signal.
The settings for the recording signal (i.e., input signal),
[0.0   ]
[1]
%
Betacam playback signal, and composite output signal (i.e.,
|
output signal) are made separately.
7.5%
When the input signal, Betacam playback signal, and output
1
1
signal have all been set to Master (i.e., they are displayed as
|
MASTER), the level specified by the MASTER LEVEL sub
10.0%
5
1
item (0% to 10.0%) is subtracted from the setup level of the
(in 0.5% steps)
input and Betacam playback signals, and added to the setup
[0]
[MASTER]
level of the output signal.
1
0.0%
The subtraction of setup level for the input signal is only done
|
for video input signals with a V/S ratio of 10:4, Betacam CAV
10.0%
input signals (set by menu), and D-2 format input signals
5
1
(Option), and not for other signals.
(in 0.5% steps)
Subtraction of the setup level for input signals can be
[0]
[remove]
disabled by setting CNT of the V.REMOTE menu (displayed
1
throu
as REMOTE) to OFF.
[0]
[MASTER]
1
0.0%
|
10.0%
5
1
(in 0.5% steps)
[0]
[MASTER]
1
0.0%
|
10.0%
5
1
(in 0.5% steps)
[0]
[–3 to +3 dB]
Specifies the variable range of the VIDEO and CHROMA
1
level when K19 is set to LOCAL.
Wide
0: –3 to +3 dB
1: –∞ to +3 dB
A-27