Chapter 3: Calibration

3.4 Dealer calibration

The Dealer calibration procedures enable the following parameters to be set:
• Wind angle and speed response.
• Wind speed calibration.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the
approximately 12 seconds, to select the Dealer calibration entry page (see
calibration
buttons to proceed with the calibration. As the calibration progresses, use the
button to move from screen to screen.

Response settings

The response values for wind speed and angle, determine the frequency at which
information is updated. A low number provides a smooth response and a high
number a much livelier response with rapid pointer movement.
Use the < (decrement) and > (increment) buttons to set the required value.
Response values are from 1 to 15 .

Wind speed

The Wind speed and Wind speed calibration screens are used to set the correct
value for the wind speed. On entry (from the Wind speed response screen), the
current value for wind speed is displayed. Set the correct wind speed value, by
applying a calibration factor as follows:
1. Use the < (decrement) and > (increment) buttons to switch from the Wind
speed screen to the Wind speed calibration screen.
2. Use the < (decrement) button or > (increment) button to set the wind speed
calibration factor to 0.7 .
3. Timeout to the Wind Speed screen, and if further adjustment is necessary,
repeat steps 1 and 2.
diagram, sheets 1 and 2). Then momentarily press the < and >
and set buttons together for
23