Connect Input/Output (I/O) Signals; Connect Pti Signals; Connect Eri And Eeo Signals - Graco HydroShield 26D030 Manual

Auto conversion kit
Table of Contents

Advertisement

Connect Input/Output (I/O) Signals

Connect the isolation cabinet to system components to
send and receive automatic signals. See Overview,
page 3.

Connect PTI Signals

Connect a 5/32 in. air line signal from the applicator's
paint trigger signal to the PTI bulkhead fitting (L) on the
side of the isolation cabinet. See F
1. Tap into the paint trigger air line going to the spray
gun.
2. Run a 5/32 in. air line from the spray gun's paint
trigger line to the isolation cabinet.
3. Plug the 5/32 in. air line into the PTI bulkhead fitting
(L) on the right side of the system.

Connect ERI and EEO Signals

Choose either pneumatic or electric communication
for electrostatic operation signals (ERI and EEO).
Pneumatic ERI and EEO Option
1. Connect a 5/32 in. air line from the EEO bulkhead
fitting (J) to the input of the device that activates
electrostatics.
2. Connect a 5/32 in. air line to the ERI bulkhead
fitting (K). Supply air pressure above 70 psi (0.5
MPa, 5.0 bar) to activate the input.
J
L
F
. 6 Pneumatic bulkhead locations
IG
3A8812B
. 6.
IG
K
Electric ERI Option
1. Run a 24 VDC signal wire and a ground wire
through the I/O strain relief ports on the right side of
the system.
F
. 7 Electrical port connections
IG
2. Feed the wires through the top right opening in the
electronics control panel.
3. Connect the 24 VDC signal wire to A1+ of the ERI
optocoupler (A).
4. Connect the ground wire to A2– of the ERI
optocoupler (A). Apply 24 VDC to A1+ to activate
the input. See system manual for grounding
instructions.
F
. 8 Terminal block wiring
IG
Connect Input/Output (I/O) Signals
9