Clearray® Bulb Replacement And Quartz Tube Maintenance - Sundance Spas MARIN 880 Series Owner's Manual

Hide thumbs Also See for MARIN 880 Series:
Table of Contents

Advertisement

880 Series
WARNINGS:
!
• Do not operate the UV-C emitter when it is removed from the appli-
ance enclosure.
• This appliance contains a UV-C emitter.
• Unintended use of the appliance or damage to the housing may
result in the escape of dangerous UV-C radiation. UV-C radiation
may, even in little doses, cause harm to the eyes and skin.
• Appliances that are obviously damaged must not be operated.
• Read the maintenance instructions before opening the appliance.
14.4
CLEARRAY® Bulb Replacement and Quartz Tube
Maintenance
Important: It is MANDATORY that the UV bulb is replaced and the
quartz tube be cleaned every 12 months to maintain optimum
performance.
1
DANGER:
!
POSITION!
!
DANGER:
CLEANING THE QUARTZ TUBE!
WARNING:
!
REMOVING FROM QUARTZ TUBE.
DANGER:
!
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
UV bulb replacement and quartz tube maintenance:
Note: Location of CLEARRAY System and connection may vary by
model.
1. Turn the breaker to the spa OFF. DRAIN YOUR SPA.
Note: If you are only replacing the UV bulb then the spa
does not have to be drained. You will need to drain it if
you are replacing or cleaning the quartz tube.
78
4
2
3
5
11
12
TURN THE SPA BREAKER TO THE OFF
DRAIN THE SPA IF YOU ARE REPLACING OR
ALLOW LAMP TO COOL DOWN PRIOR TO
NEVER LOOK AT THE LIT BULB. THIS CAN
9 10
8
6
7
FIGURE 1
FIGURE 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Capri 880 series

Table of Contents