PROBLEM
None of the
components
operate (i.e.
pump, blower,
light)
Pump does not
operate and icon
does
AIR LOCK
Pump Priming Instructions:
This method must be used for the jets pumps because these pumps
are not connected to the main filter system in any way.
1. Turn off the power to the spa.
2. Remove the handle from the massage selector supplied by the pump
you are priming.
3. Loosen the massage selector's cap slightly (counterclockwise),
listening for the air to seep out.
4. Tighten the cap finger tight, replace the handle, and turn the spa's
power back on.
CAUTION: If freezing conditions exist and pump is not operational,
take measures to protect the system from freeze damage. See Section
titled "Winterizing," page 74.
PROCEDURE
Check the control panel lights.
1. If there are letters or symbols displayed on
the screen, refer to the previous section to
determine meaning and action required.
2. If nothing appears on the screen:
A. Check the household circuit breaker.
B. Contact you Sundance Spas dealer or
qualified service technician.
Depress JETS Button.
1.
If no sound is detected or if a buzzing sound
is detected, turn off power to the spa and
contact your authorized dealer or qualified
service technician.
2.
If motor operates, but now water flows to
jets:
A. Pump may not be properly primed. See
instructions below.
B. Contact your Sundance Spas dealer or
qualified service technician.
Purge "air lock" from circulation pump intake by
removing filter cartridge. Hold your garden hose
over the filter cartridge wall fitting while using a rag
as a seal around hose end. Ask a helper to turn on
water for 30 seconds, then turn off. Reinstall filter
cartridge and check spa.