14.2

Sanitizing

To destroy bacteria and organic compounds in the hot tub water, a
sanitizer must be used regularly. Your Sundance hot tub is equipped with
the Brominator™, a special compartment built into the floating skimmer
gate to hold the SunPurity™ mineral cartridge designed specifically for
your hot tub or bromine tablets. By regulating the number of bromine
tablets in the Brominator you can control the amount of bromine, which is
actively working, in your hot tub water. A bromine residual of no less than
2.0 ppm is generally considered desirable. A two-part bromine system or
granular chlorine (dichlor) are also acceptable sanitizers. When adding
spa shock (chlorine or non-chlorine) or pH balancing chemicals, activate
the jets pump(s) and leave the spa cover open for a minimum of 20 min-
utes. By doing this you will allow excess chemical vapors to exit the spa,
protecting pillows and plastic knobs from chemical attack.
WARNING:
!
OR ENTRAPMENT!
Never leave your hot tub unattended for any reason while the
cover is open and accessible, especially to small children and
animals!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for
any reason! These chemical may damage components within
your hot tub, burn or irritate your skin, create a rash, and void
the manufacturer warranty for your spa.
14.3
CLEARRAY® Water Purification System
Your new hot tub has our water purification system
factory installed that will begin disinfecting your water
instantly. CLEARRAY Water Purification System is exclusive
technology utilizing natural ultraviolet technology to sanitize
your water, disinfecting bacteria, viruses, and algae in portable
hot tubs. The ultraviolet light otherwise known as UV-C or
germicidal light inactivates the microorganisms by disrupting
the DNA so that it cannot reproduce and is considered lifeless.
The ballast is the power supply for the purification system; it
has two LED indicator lights the green indicating incoming
power flow and the red indicating the system is properly working.
CLEARRAY is standard for all models.
After a year the bulb must be replaced. A message will appear on the
LCD display when the time allotted has expired. In order to clear the
message, a new UV bulb needs to be installed and the timer must be
reset (Sec. 12.6, page 61).
RISK OF PERSONAL INJURY, DROWNING
880 Series
WARNING!
DO NOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
77