Network and system integration

4.2 System configuration via PROFINET/PROFIBUS with CM

4.2
System configuration via PROFINET/PROFIBUS with CM
Figure 4-1
System characteristics
● The PROFINET/PROFIBUS connection is made via the CM interface of the optical reader
and a communication module.
● PROFINET IO/PROFIBUS DP-V1 is connected to an S7 controller.
● The optical reader is controlled via PROFINET IO/PROFIBUS DP-V1 using the Ident
profile block by the S7 controller.
● The result is output via PROFINET IO/PROFIBUS DP-V1 to the S7 controller.
● The optical reader is supplied with power via the communication module.
● The optical reader is triggered either via digital I/O, S7 controller or via the built-in auto-
trigger function.
● A PC/PG is connected via the Ethernet interface to allow adjustment of the device.
54
Optical sensor or light barrier (for trigger signal)
Object with code
Example: System configuration via PROFINET IO/PROFIBUS DP-V1 with
communication module
Operating Instructions, 05/2019, C79000-G8976-C494-02