Siemens SIMATIC MV550 S Operating Instructions Manual page 88

Table of Contents

Advertisement

Commissioning
7.2 Connecting using the "CONNECT" button
Once the initial connection has been established, assign an IP address to the reader
("Settings > Communication > Interfaces > Ethernet"). To continue working with the reader,
start the WBM by entering the IP address in your Web browser.
Connecting an optical reader and establishing a connection (point-to-point connection to PC)
1
st
3
rd
NOTICE
Possible faults when operating as a DHCP/DNS server
Note that the optical reader is set up as a DHCP/DNS server when establishing a
connection via the "CONNECT" button. This may interfere with communication in an
existing network. Another DHCP/DNS server in the network must not be enabled.
If the IP address of the reader is changed after the connection has been established, the
connection is aborted. In addition, the "CONNECT" function is disabled. This function can
be enabled again via the "Settings > Options > Extras" menu.
88
4
th
2
nd
5
th
Operating Instructions, 05/2019, C79000-G8976-C494-02
SIMATIC MV500

Advertisement

Table of Contents
loading

Table of Contents