Commissioning
7.5 Selecting connection alternatives
Operating the optical reader in PROFINET mode ("X1 LAN1")
In PROFINET mode, you can do the following with the optical reader:
● Connect to the PC or the PG in your existing PROFINET IO network.
● Integrate as a device in a PROFINET IO network.
● Integrate as a device in a PROFINET IO network with an existing IP address (can be set
in the configuration software, e.g. TIA Portal).
● Assign the IP configuration of the PROFINET IO controller.
NOTICE
Setting the IP address for "X2 LAN2"
Note that you can only set the IP address for the "X2 LAN2" interface via the WBM.
NOTICE
Ethernet interfaces in different subnets
Note that you must operate the Ethernet interfaces "X1 LAN1" and "X2 LAN2" in two
different subnets. If you do not comply, you cannot save the changes in the WBM, or if you
use PST, the IP address of the "X2 LAN2" interface is discarded.
98
Operating Instructions, 05/2019, C79000-G8976-C494-02